Flow Monitor Result is not showing in ns3 simulation - ns-3

Currently i m using ns-3.19 for my simulation
I have code of PMIPV6. It is running on my friend system perfectly and showing me Flow Monitor output on the terminal. But when i m running on my system code is running perfectly fine but it is not showing me output of Flow Monitor just like it is showing me on my friend's system. Please help me what i have to do to see the output.
Code file is attached.
Note: Both systems are using same version of ns and ubuntu. Even files are also same. Output of my friend system
Code i have here it is https://drive.google.com/file/d/1LEMfjUXLj4r7W3wLTBsc99PfyAtouEVX/view?usp=sharing

Try to use it in NS-3.20. It may be a compatibility with NS-3 version.
Follow the below link for more information. Thank you.
https://www.nsnam.org/doxygen/

Related

How to set DMM4040 multimeter into remote mode?

I have developed a labview program to set DMM4040 series multimeter into remote mode and it is not working. But when I did the same thing by NI-MAX It works fine.
I don't understand what is the problem with this code.
You would need to show us the code first.
Are you using the instrument driver from the NI IDNet (Instrument Driver Network)?
If not, I strongly suggest you start with the driver, which for your instrument can be found here:
http://sine.ni.com/apps/utf8/niid_web_display.model_page?p_model_id=16513

Running the exploration result file of the TestSuite machine(Spec Explorer) in a Console Application

I'm having a problem while trying to follow a example of Spec Explorer, while using Visual Studio 2012.
I've been following this link, but I get stuck on the running the Spec Explorer file with a Console Application.
My problem starts at the next sentence:
"Running this part of the program on the exploration result file of the TestSuite machine in the SMB2 project results in output as below:"
I don't know how to do this, but they don't elaborate on it, does anyone of you know how I should do this?
I assume you are using Visual Studio (VS)2012.
Then I guess you tried already the "RequirementReport" example of Spec Explorer.
This should give you the same possibilities and a running example (using VS2010).
I assume you tried this example, but it was not working (due to VS2012).
Then you tried it with this article in your link.
You're interested in just a report of an exploration result. You're not playing with the idea any more of creating your own full blown path coverage strategy. Right?
You created a new console-application-C#-project and copied the program code from the end of the article into it.
You are able to compile. But you forgot to replace "args[0]" with the full qualified path to an .seexpl-file! Right?
A lot of guessing, but I need 4 more points until I can ask questions in a comment ...

Chrome OS bug - file select dialog (for uploads) 'stuck'

The best way to sum up the issue would be with a screenshot, but unfortunately my screenshots auto-save to downloads and so I can't upload them. What's happening is that when I enter the 'file select' dialog in trying to upload a file, it's automatically in the 'drive' folder and won't move to any other folder. I've tried restarting and resetting my machine, tried the upload process on a bunch of different platforms, tried using the other user account on my machine, tried updating my software, but none of these have made any difference. I can get into my downloads folder and open files from it fine outside of this context, and I can workaround by using the drag-and-drop to upload on platforms which have this feature, but otherwise I'm stuck.
I've googled extensively to see if anyone else is having this issue and have found this thread: https://productforums.google.com/forum/#!topic/chromebook-central/d7g9EEDsr8w but there's no helpful solution there (recommended a powerwash but the asker has already done this several times). I've also tried to find a solution with the help of my (programmer) employer, but no luck so he recommended asking here. It seems like it wouldn't be a hardware issue when I can still access the folder outside of this specific function, but if it were a problem with the running system it seems it would be happening across the board and therefore show up more in a google? If anyone has any suggestions I'd be very grateful as it's getting quite tiresome having to drag and drop things into Facebook messages to get them uploaded! The machine is less than a year old so if I can't find any solution I'll see about getting it replaced under warranty. Thanks in advance for any help, and please let me know if there's any key info I've left out!
Machine: Samsung Chromebook XE303C12
OS: Version 38.0.2125.110

Autoingestion.class has stopped creating report files

A few month ago i wrote some scripts to fetch the itunes connect sales reports automatically. Today i noticed that the scripts has stopped working correctly, so i searched for the problem.
Obviously the Autoingestion Tool from Apple (Autoingestion.class) has stopped to create the expected output files...
Usage Example:
java Autoingestion user *pw* vendor Sales Daily Summary 20130401
Syntax is still correct regarding http://www.apple.com/itunesnews/docs/AppStoreReportingInstructions.pdf
The tool runs fine without any errors. Just the expected output file is missing :(.
To except problems with java - i tested the tool on different platforms with different JVM versions.
Is anyone else experiencing this problem?
I had the same issue, but per your own comment, I tried it on another box with an up to date JRE, I believe, and it worked. (I'd tried it on my dev box, but running it on the live box worked. Makes sense.)
Just adding, this is the output we want to see:
$ java Autoingestion autoingestion.properties <vendor> Sales Daily Summary 20130801
S_D_<vendor>_20130801.txt.gz
File Downloaded Successfully
I'm inclined to think there should always be output from running Autoingestion. I actually had the wrong credentials when I ran it at first, but it couldn't even tell me that, in the wrong environment.

USRP2 Overflow problem

I am trying to capture the wlan samples from gnuradio-companion. I have configured the USRP Soource with the following :
Ch0 Gain = 50dB
device addr : 192.168.10.3
Center Frequency : 2.437GHz
Sample Rate : 11M
But , when I execute the model, I receive the Overflow message at the console. Any hints whether the configuration is proper for collecting the samples ?
Here is the attached model:
An 'overflow' indicates that your computer is receiving data faster than it is capable of processing it.
I realize this is an old question, but for anyone else that looks at this question hoping to find something useful, remember that your computer must process the samples. Here, you are dumping the samples into two graphical sinks, and also writing to your hard disk at 11 MSps (11e6 * 32bits = 352 MBits / sec).
If you are on a machine that can't keep up with that, the overflows would be expected!
You do not state if you run as root or not, but for me running as root solved the problem for me. Running as root gives you more privelegies and so you can use more features of the processor.