I've been running a standalone chrome selenium server in AWS for a while, and am used to seeing the active browser sessions listed in the web console (located at <selenium_host>:4444/wd/hub/static/resource/hub.html) where I can see screenshots, kill sessions and more.
I recently migrated over to running the standalone selenium server inside a docker container and noticed that the web console is still visible but all the buttons are disabled and no sessions appear even when active browser sessions are running.
There are no issues with the selenium functionality itself, I just would like to be able to view the active sessions and cannot figure out how to fix this.

Related

Tests running silently without window appearing

Apologies, I'm still fairly new to selenium so please bear with me as I explain this.
Currently my selenium tests are running on a remote machine but no window opens when I'm remotely logged into that machine!
My setup is:
Remote machine has 2 admin users with Selenium Grid2 and a node as a windows service.
The machine is running windows server 2012 with the services having Interactive services enabled.
I am using Selenium 2.42.1 with IEDriver version 2.42.0
Tests are being built and run remotely on our build server.
I think that's everything, if there's any more information then please let me know as I'd really like to know why I cannot view my tests running.
Just for clarification, the tests are running and they successfully pass or fail where necessary, but I just can't see it if I'm remote logged into the machine.
UPDATE
There has been some interesting progress on this issue but still no resolution.
I decided to try and run a node from command line and funny enough the tests run with no problems and the browser window is displayed.
So if anyone has any idea why a browser window would appear when running a node from command line but not when running a node as a service would be great.
I'm using java service wrapper to create my service and im using the same nodeconfig.json when running the node.
This can happen when you are running the node as a windows service. There is an option in service to say whether the job should run in background or interact with desktop. Check that and you should see the windows.

Running selenium on Windows server 2008

I'm trying to automate some selenium tests.
I can run them locally in my machine, but when I try to run them in windows server 2008 (the server in which our CI server runs) the Firefox window only opens if I open the cmd line with admin privileges. I don't wan't this to run with admin privileges, so the question is: what do I need to do to be able to open Firefox window with a regular user?
There is nothing you can do about that. Starting with Windows Vista, Microsoft locked down the "interactable" sessions and so running WebDriver grid hub as a service which starts browsers in a desktop session will not work unless you are using Windows XP. So, what you need to do is have multiple grid nodes running in the foreground and leave those desktop sessions open in Windows 2008. Also, with Jenkins, running Selenium tests (without a grid) will exhibit the same problem where you'd have to run Jenkins in the foreground.
Windows says "By default, services use a noninteractive window station and cannot interact with the user. However, an interactive service can display a user interface and receive user input.". Also, "All services run in Terminal Services session 0. Therefore, if an interactive service displays a user interface, it is visible only to the user who connected to session 0. " See this site for this info.
The holy grail would be to write a Java program using SystemTray and then have the tray application auto-start a grid node session in the foreground when a desktop session starts. Just an idea since VisGrid cannot do this.
On Linux, there is a way to use xvfb to run grid as a service and run browsers in a headless session, but its a complex setup I think and I have never tried it. It's not very much different that the Windows situation anyway and I think the windows setup is easier.

Selenium Grid 2 Jenkins CI automation Single sign on application

I am currently working on an application which has single sign on. You have to be logged in using the LAN or internal wireless Network to access the web page. My architecture team has created the Jenkin Job with Selenium Grid for the automation.
We have Jenkins slave created on a remote server. Now, when I try to run my tests, I get the error message and the tests does not run. But when I run the http://www.google.com page, the tests run successfully. Has anyone faced this issue before?

Windows service that interacts with desktop screen resolution

I configured Jenkins as Selenium Grid and some Jenkins Nodes as Selenium Nodes (controlled by Jenkins Selenium plugin).
The nodes are connected with the option "Let Jenkins control this Windows Slave as Windows Service".
The service is defined automatically at the node as "interact with desktop".
Jenkins slave enables Selenium remote driver service
The problem is that the resolution of UI tests is really low (1036 x 780) where we need (1600x1200).
Opening an RDP session doesn't help since the service was started by Jenkins.
How to change the default resolution of windows service that can interact with Desktop?
I had the same problem as yours. Difference was I also have GUI automation besides Selenium tests. I ended up installing VNC service on all the nodes and wrote a script to change the desktop resolution before running any tests. However the highest resolution by doing that we got is 1280x1024, which resolved my problem.
If you don't mind giving up running Jenkins Slave as Windows Service you can use this way:
Jenkins on Windows and GUI Tests without RDC
Still - that would make you maintain an open RDP session that runs Jenkins JNLP process... So that solution is working, but not very optimal.

Sikuli, selenium testing on Jenkins: Allow the browser to be launched in the foreground, as it is when i run it from development machine?

The issue is that Sikuli's image recognition capabilities only work when the target of the Sikuli tests is in the foreground and it has full access to the mouse. In its current configuration, Jenkins projects are never visible from the desktop of the windows slave node.
The way my current automated testing suite is setup right now, about 30 tests are written using only selenium. In the final two tests, selenium starts a webdriver (currently chromedriver but can be firefox or IE) and navigates to the right pages and Sikuli does its thing from there. Both use the java language bindings.
Currently Sikuli appears to be installed correctly, but when it is asked to click through a list of screenRegions supposedly populated by matching the desktop with a target image, it immediately throws a NPE.
How do I change my Jenkins setup on my windows 7 slave to allow the browser to be launched in the foreground, as it is when i run it from my windows 7 development machine?
So you've got a development machine where Sikuli works, and a test machine where Jenkins runs Sikuli and it doesn't work.
I had this same setup (with the Sikuli tester/Jenkins slave running Windows 7). What worked for me was to have the test machine run a VNC server, log in as a the tester account over VNC, and launch the Jenkins slave as a regular application and not a service. I used UltraVNC server.
As far as I could tell, the problem stems from Windows' security measures, which are designed to prevent a remote user from controlling your machine without your presence.
If you run Jenkins as a service, it doesn't get a real desktop allocated to it. The script will run, but (as you're seeing) Sikuli won't actually be able to find anything because there's nothing for it to look at. (Selenium is inspecting the page content programmatically, so it doesn't mind that the page is not actually displayed on any screen.)
You can also just run Jenkins and leave yourself logged in, and skip the VNC server. I wanted to run the machine without a monitor or keyboard and still have control, though. If that's your goal as well, you can't use Remote Desktop, because it allocates a new desktop on connection and then destroys it when you disconnect. (So Jenkins will work when you're watching and fail when you leave for the night. Very frustrating!)
As a side benefit, if you do it this way you can connect over VNC and watch Jenkins as it's running the test.
make the slave machine remote desktop to itself.
run the jenkins salve as program in that session
cmd /c start java -jar slave.jar -jnlpUrl http....slave-agent.jnlp -secret ... (find it in your jenkins master (shown when the slave service is down)