deleteAllCookies or cleanCookie causes UnreachableBrowserException when using InternetExplorerDriver - selenium

I have set up a small test suite with geb, everything is working fine with chrome and firefox, but now i wanted to extend the browsers i execute the tests on with IE and the tests always fail because of remaining cookies from previous tests (I'm still logged in after executing the login test)
To load the IEDriver i use the webdrivermanager from bonigarcia which executes Version 2.53.1.0 of InternetExplorerDriver.
Snippet from my GebConfig:
environments {
ie {
InternetExplorerDriverManager.getInstance().setup(Architecture.x32)
driver = { new InternetExplorerDriver() }
}
My test setup looks like this:
def setup() {
resetBrowser()
Database.resetDatabase()
}
The method resetBrowser() is from Geb and does this:
void resetBrowser() {
if (_browser?.config?.autoClearCookies) {
_browser.clearCookiesQuietly()
}
_browser = null
}
And here's my cleanup (also tried it without it, didn't change anything):
def cleanup() {
CachingDriverFactory.clearCacheAndQuitDriver()
}
resetBrowser() should delete the cookies, but I read, that only cookies from the current domain will be deleted. So I thought adding something like browser.clearCookies(browser.baseUrl) or browser.clearCookies("http://localhost:8080/") before, after or instead of resetBrowser() should work. But as soon as I add this line, the IEDriver stops working with the following exception (same exception is thrown when i use driver.manage().deleteAllCookies()):
org.openqa.selenium.remote.UnreachableBrowserException: Error communicating with the remote browser. It may have died.
Build info: version: '2.53.0', revision: '35ae25b1534ae328c771e0856c93e187490ca824', time: '2016-03-15 10:43:46'
System info: host: 'MiiKEs', ip: '192.168.0.123', os.name: 'Windows 10', os.arch: 'amd64', os.version: '10.0', java.version: '1.8.0_66'
Driver info: driver.version: RemoteWebDriver
Capabilities [{browserAttachTimeout=0, ie.enableFullPageScreenshot=true, enablePersistentHover=true, ie.forceCreateProcessApi=false, ie.forceShellWindowsApi=false, pageLoadStrategy=normal, ignoreZoomSetting=false, ie.fileUploadDialogTimeout=3000, version=11, platform=WINDOWS, nativeEvents=true, ie.ensureCleanSession=false, elementScrollBehavior=0, ie.browserCommandLineSwitches=, requireWindowFocus=false, browserName=internet explorer, initialBrowserUrl=http://localhost:21317/, javascriptEnabled=true, ignoreProtectedModeSettings=false, enableElementCacheCleanup=true, unexpectedAlertBehaviour=dismiss}]
Session ID: 75c52825-b9e6-4876-a1f9-454b450b839e
at org.openqa.selenium.remote.RemoteWebDriver.execute(RemoteWebDriver.java:665)
at org.openqa.selenium.remote.RemoteWebDriver.execute(RemoteWebDriver.java:701)
at org.openqa.selenium.remote.RemoteWebDriver$RemoteWebDriverOptions.deleteAllCookies(RemoteWebDriver.java:773)
at TestSpec.register test(TestSpec.groovy:84)
Caused by: org.openqa.selenium.WebDriverException: org.apache.http.conn.HttpHostConnectException: Connect to localhost:21317 [localhost/127.0.0.1, localhost/0:0:0:0:0:0:0:1] failed: Connection refused: connect
Build info: version: '2.53.0', revision: '35ae25b1534ae328c771e0856c93e187490ca824', time: '2016-03-15 10:43:46'
System info: host: 'MiiKEs', ip: '192.168.0.123', os.name: 'Windows 10', os.arch: 'amd64', os.version: '10.0', java.version: '1.8.0_66'
Driver info: driver.version: RemoteWebDriver
at org.openqa.selenium.remote.service.DriverCommandExecutor.execute(DriverCommandExecutor.java:91)
at org.openqa.selenium.remote.RemoteWebDriver.execute(RemoteWebDriver.java:644)
... 3 more
Caused by: org.apache.http.conn.HttpHostConnectException: Connect to localhost:21317 [localhost/127.0.0.1, localhost/0:0:0:0:0:0:0:1] failed: Connection refused: connect
at org.apache.http.impl.conn.DefaultHttpClientConnectionOperator.connect(DefaultHttpClientConnectionOperator.java:151)
at org.apache.http.impl.conn.PoolingHttpClientConnectionManager.connect(PoolingHttpClientConnectionManager.java:353)
at org.apache.http.impl.execchain.MainClientExec.establishRoute(MainClientExec.java:380)
at org.apache.http.impl.execchain.MainClientExec.execute(MainClientExec.java:236)
at org.apache.http.impl.execchain.ProtocolExec.execute(ProtocolExec.java:184)
at org.apache.http.impl.execchain.RetryExec.execute(RetryExec.java:88)
at org.apache.http.impl.execchain.RedirectExec.execute(RedirectExec.java:110)
at org.apache.http.impl.client.InternalHttpClient.doExecute(InternalHttpClient.java:184)
at org.apache.http.impl.client.CloseableHttpClient.execute(CloseableHttpClient.java:71)
at org.apache.http.impl.client.CloseableHttpClient.execute(CloseableHttpClient.java:55)
at org.openqa.selenium.remote.internal.ApacheHttpClient.fallBackExecute(ApacheHttpClient.java:144)
at org.openqa.selenium.remote.internal.ApacheHttpClient.execute(ApacheHttpClient.java:90)
at org.openqa.selenium.remote.HttpCommandExecutor.execute(HttpCommandExecutor.java:142)
at org.openqa.selenium.remote.service.DriverCommandExecutor.execute(DriverCommandExecutor.java:82)
... 4 more
Caused by: java.net.ConnectException: Connection refused: connect
at java.net.DualStackPlainSocketImpl.socketConnect(DualStackPlainSocketImpl.java:85)
at java.net.AbstractPlainSocketImpl.doConnect(AbstractPlainSocketImpl.java:350)
at java.net.AbstractPlainSocketImpl.connectToAddress(AbstractPlainSocketImpl.java:206)
at java.net.AbstractPlainSocketImpl.connect(AbstractPlainSocketImpl.java:188)
at java.net.PlainSocketImpl.connect(PlainSocketImpl.java:172)
at java.net.SocksSocketImpl.connect(SocksSocketImpl.java:392)
at java.net.Socket.connect(Socket.java:589)
at org.apache.http.conn.socket.PlainConnectionSocketFactory.connectSocket(PlainConnectionSocketFactory.java:74)
at org.apache.http.impl.conn.DefaultHttpClientConnectionOperator.connect(DefaultHttpClientConnectionOperator.java:134)
... 17 more

My Problem was not, that the cookies are not deleted, it was that LocalStorage is not cleaned!
To clean LocalStorage Geb doesn't offer any functionality yet, but this can be achieved with the following method which can be called in the setup() routine:
def clearLocalStorage() {
//first navigate to any page within the domain to which you want to clear the LocalStorage
// baseUrl can be set in
go(browser.baseUrl)
js.exec("localStorage.clear()") // and then just clear it
}
The suggestion to use the WebStorage interface of WebDriver is as far as I anderstood not possible till InternetExplorerDriver does not implement this interface!

Related

session null does not exist (WARNING: The server did not provide any stacktrace information

I am actually new to selenium, I have automated the website successfully using Firefox driver but when I tried the same code in IE am getting the subjected error in the driver.get(URL) line I used two different type simple code to open the browser and navigate to google which is not working.
please help me resolve this issue with IEDriver.
code 1:
System.setProperty("webdriver.ie.driver", "D:\\otherdata\\Selenium\\IEDriverServer.exe");
WebDriver driver= new InternetExplorerDriver();
driver.get("www.google.com");
code 2:
DesiredCapabilities IEcaps = DesiredCapabilities.internetExplorer();
IEcaps .setCapability(
InternetExplorerDriver.INTRODUCE_FLAKINESS_BY_IGNORING_SECURITY_DOMAINS,
true);
File SrcFile= new File("D:\\other data\\Selenium\\IEDriverServer.exe");
System.setProperty("webdriver.ie.driver", SrcFile.getAbsolutePath());
WebDriver driver = new InternetExplorerDriver(IEcaps );
driver.get("www.google.com");
ERROR:
Started InternetExplorerDriver server (32-bit)
3.5.1.0
Listening on port 5424
Only local connections are allowed
Exception in thread "main" org.openqa.selenium.remote.SessionNotFoundException: session null does not exist (WARNING: The server did not provide any stacktrace information)
Command duration or timeout: 3 milliseconds
Build info: version: '2.53.1', revision: 'a36b8b1', time: '2016-06-30 17:32:46'
System info: host: 'MGK-PC', ip: '192.168.1.108', os.name: 'Windows 10', os.arch: 'amd64', os.version: '10.0', java.version: '1.8.0_91'
Driver info: org.openqa.selenium.ie.InternetExplorerDriver
Capabilities [{capabilities={acceptInsecureCerts=false, browserVersion=11, se:ieOptions={nativeEvents=true, browserAttachTimeout=0, ie.ensureCleanSession=false, elementScrollBehavior=0, enablePersistentHover=true, ie.browserCommandLineSwitches=, ie.forceCreateProcessApi=false, requireWindowFocus=false, initialBrowserUrl=http://localhost:5424/, ignoreZoomSetting=false, ie.fileUploadDialogTimeout=3000, ignoreProtectedModeSettings=true}, browserName=internet explorer, pageLoadStrategy=normal, unhandledPromptBehavior=dismiss, platformName=windows, setWindowRect=true}, sessionId=668e028c-b9e5-4ddc-8d0a-f2d61ac62bde, platform=ANY}]
Session ID: null
at sun.reflect.NativeConstructorAccessorImpl.newInstance0(Native Method)
at sun.reflect.NativeConstructorAccessorImpl.newInstance(Unknown Source)
at sun.reflect.DelegatingConstructorAccessorImpl.newInstance(Unknown Source)
at java.lang.reflect.Constructor.newInstance(Unknown Source)
at org.openqa.selenium.remote.ErrorHandler.createThrowable(ErrorHandler.java:206)
at org.openqa.selenium.remote.ErrorHandler.throwIfResponseFailed(ErrorHandler.java:158)
at org.openqa.selenium.remote.RemoteWebDriver.execute(RemoteWebDriver.java:678)
at org.openqa.selenium.remote.RemoteWebDriver.get(RemoteWebDriver.java:316)
at New.IE_Test.main(IE_Test.java:27)

Unable to run selenium with IE browser via Jenkins

Selenium version 3.5
IEDriverserver - 3.5.0
IE version - 11
Jenkins version 2.75
private static final WebDriver WebDriverRefrence = null;{
}
public WebDriver driver ;
#BeforeTest
public void launchBrowser() {
Logger.getRootLogger().setLevel(Level.OFF);
System.setProperty("webdriver.ie.driver","C:\\AUTOMATION\\IEDriverServer.exe");
//Turn ON Protected Mode for the IE Browser
DesiredCapabilities aots = DesiredCapabilities.internetExplorer();
aots.setCapability("nativeEvents",false);
aots.setCapability(InternetExplorerDriver.INTRODUCE_FLAKINESS_BY_IGNORING_SECURITY_DOMAINS,true);
driver = new InternetExplorerDriver(aots)
driver.get("https://www.gmail.com");
}
#Test
public void Test_case_001() throws InterruptedException {
driver.findElement(By.id("identifierId")).sendKeys("abc");
Thread.sleep(1000);
driver.findElement(By.xpath(".//*[#id='identifierNext']/div[2]")).click();
Thread.sleep(3000);
driver.findElement(By.xpath(".//*[#id='password']/div[1]/div/div[1]/input")).sendKeys("XXXXXX");
Thread.sleep(2000);
driver.findElement(By.xpath(".//*[#id='passwordNext']/div[2]")).click();
}
}
I have a simple Selenium code to login to Gmail.
I'm able to run successfully from eclipse (IE browser)
I'm able to run successfully from eclipse (FF browser)
I'm able to run successfully via Jenkins (FF browser)
But when I use IE browser and run via Jenkins, it fails.
The code and error is below. Don't know why element is not found when running via Jenkins.
Here is the error from testing output file :
-<test-method finished-at="2017-09-06T13:47:33Z" started-at="2017-09-06T13:47:26Z" duration-ms="6405" name="Test_case_001" signature="Test_case_001()[pri:0, instance:test2.practice#4c75cab9]" status="FAIL">
-<exception class="org.openqa.selenium.NoSuchElementException">
-<message>
-<![CDATA[Unable to find element with xpath == .//*[#id='password']/div[1]/div/div[1]/input
For documentation on this error, please visit: http://seleniumhq.org/exceptions/no_such_element.html
Build info: version: 'unknown', revision: 'unknown', time: 'unknown'
System info: host: 'DESKTOP-E0D9KLG', ip: '135.70.196.248', os.name: 'Windows 10', os.arch: 'amd64', os.version: '10.0', java.version: '1.8.0_92'
Driver info: org.openqa.selenium.ie.InternetExplorerDriver
Capabilities [{acceptInsecureCerts=false, browserVersion=11, se:ieOptions={nativeEvents=true, browserAttachTimeout=0.0, ie.ensureCleanSession=false, elementScrollBehavior=0.0, enablePersistentHover=true, ie.browserCommandLineSwitches=, ie.forceCreateProcessApi=false, requireWindowFocus=false, initialBrowserUrl=http://localhost:43511/, ignoreZoomSetting=false, ie.fileUploadDialogTimeout=3000.0, ignoreProtectedModeSettings=true}, browserName=internet explorer, pageLoadStrategy=normal, unhandledPromptBehavior=dismiss, javascriptEnabled=true, platformName=windows, setWindowRect=true, platform=ANY}]
Session ID: 1baa5458-8f37-4e13-9119-08b88aba17f0
*** Element info: {Using=xpath, value=.//*[#id='password']/div[1]/div/div[1]/input}]]>
</message>
-<full-stacktrace>
-<![CDATA[org.openqa.selenium.NoSuchElementException: Unable to find element with xpath == .//*[#id='password']/div[1]/div/div[1]/input
For documentation on this error, please visit: http://seleniumhq.org/exceptions/no_such_element.html
Build info: version: 'unknown', revision: 'unknown', time: 'unknown'
System info: host: 'DESKTOP-E0D9KLG', ip: '135.70.196.248', os.name: 'Windows 10', os.arch: 'amd64', os.version: '10.0', java.version: '1.8.0_92'
Driver info: org.openqa.selenium.ie.InternetExplorerDriver
Capabilities [{acceptInsecureCerts=false, browserVersion=11, se:ieOptions={nativeEvents=true, browserAttachTimeout=0.0, ie.ensureCleanSession=false, elementScrollBehavior=0.0, enablePersistentHover=true, ie.browserCommandLineSwitches=, ie.forceCreateProcessApi=false, requireWindowFocus=false, initialBrowserUrl=http://localhost:43511/, ignoreZoomSetting=false, ie.fileUploadDialogTimeout=3000.0, ignoreProtectedModeSettings=true}, browserName=internet explorer, pageLoadStrategy=normal, unhandledPromptBehavior=dismiss, javascriptEnabled=true, platformName=windows, setWindowRect=true, platform=ANY}]
Session ID: 1baa5458-8f37-4e13-9119-08b88aba17f0
*** Element info: {Using=xpath, value=.//*[#id='password']/div[1]/div/div[1]/input}
at sun.reflect.NativeConstructorAccessorImpl.newInstance0(Native Method)
at sun.reflect.NativeConstructorAccessorImpl.newInstance(NativeConstructorAccessorImpl.java:62)
at sun.reflect.DelegatingConstructorAccessorImpl.newInstance(DelegatingConstructorAccessorImpl.java:45)
at java.lang.reflect.Constructor.newInstance(Constructor.java:423)
at org.openqa.selenium.remote.http.W3CHttpResponseCodec.createException(W3CHttpResponseCodec.java:185)
at org.openqa.selenium.remote.http.W3CHttpResponseCodec.decode(W3CHttpResponseCodec.java:120)
at org.openqa.selenium.remote.http.W3CHttpResponseCodec.decode(W3CHttpResponseCodec.java:49)
at org.openqa.selenium.remote.HttpCommandExecutor.execute(HttpCommandExecutor.java:164)
at org.openqa.selenium.remote.service.DriverCommandExecutor.execute(DriverCommandExecutor.java:82)
at org.openqa.selenium.remote.RemoteWebDriver.execute(RemoteWebDriver.java:641)
at org.openqa.selenium.remote.RemoteWebDriver.findElement(RemoteWebDriver.java:414)
at org.openqa.selenium.remote.RemoteWebDriver.findElementByXPath(RemoteWebDriver.java:513)
at org.openqa.selenium.By$ByXPath.findElement(By.java:361)
at org.openqa.selenium.remote.RemoteWebDriver.findElement(RemoteWebDriver.java:406)
at test2.practice.Test_case_001(practice.java:79)
at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:62)
at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:43)
at java.lang.reflect.Method.invoke(Method.java:498)
at org.testng.internal.MethodInvocationHelper.invokeMethod(MethodInvocationHelper.java:85)
at org.testng.internal.Invoker.invokeMethod(Invoker.java:639)
at org.testng.internal.Invoker.invokeTestMethod(Invoker.java:816)
at org.testng.internal.Invoker.invokeTestMethods(Invoker.java:1124)
at org.testng.internal.TestMethodWorker.invokeTestMethods(TestMethodWorker.java:125)
at org.testng.internal.TestMethodWorker.run(TestMethodWorker.java:108)
at org.testng.TestRunner.privateRun(TestRunner.java:774)
at org.testng.TestRunner.run(TestRunner.java:624)
at org.testng.SuiteRunner.runTest(SuiteRunner.java:359)
at org.testng.SuiteRunner.runSequentially(SuiteRunner.java:354)
at org.testng.SuiteRunner.privateRun(SuiteRunner.java:312)
at org.testng.SuiteRunner.run(SuiteRunner.java:261)
at org.testng.SuiteRunnerWorker.runSuite(SuiteRunnerWorker.java:52)
at org.testng.SuiteRunnerWorker.run(SuiteRunnerWorker.java:86)
at org.testng.TestNG.runSuitesSequentially(TestNG.java:1215)
at org.testng.TestNG.runSuitesLocally(TestNG.java:1140)
at org.testng.TestNG.run(TestNG.java:1048)
at org.testng.TestNG.privateMain(TestNG.java:1355)
at org.testng.TestNG.main(TestNG.java:1324)

data:, shown in the chrome url bar when I execute the following Selenium ChromeWebdrive Script

data:, shown in the chrome url bar when I execute the following Selenium ChromeWebdrive Script. Is the because other instance of chrome browser are working?
import org.openqa.selenium.WebDriver;
import org.openqa.selenium.chrome.ChromeDriver;
public class ChromWebdriverWindows {
public static void main(String[] args) {
//String url = "https://www.google.co.in/";
System.getProperty("webdriver.chrome.driver", "C:\\Automation\\chromedriver_win32\\chromedriver.exe");
WebDriver drive;
drive = new ChromeDriver();
drive.get("https://www.flock.co");
}
}
Getting this error in console:
Starting ChromeDriver 2.20.353145 (343b531d31eeb933ec778dbcf7081628a1396067) on port 7264
Only local connections are allowed.
Exception in thread "main" org.openqa.selenium.WebDriverException: java.net.SocketException: Connection reset
Build info: version: 'unknown', revision: '5234b32', time: '2017-03-10 09:00:17 -0800'
System info: host: 'MDVLFARZANS', ip: '192.168.0.106', os.name: 'Windows 10', os.arch: 'amd64', os.version: '10.0', java.version: '1.8.0_121'
Driver info: driver.version: ChromeDriver
at org.openqa.selenium.remote.service.DriverCommandExecutor.execute(DriverCommandExecutor.java:91)
at org.openqa.selenium.remote.RemoteWebDriver.execute(RemoteWebDriver.java:604)
at org.openqa.selenium.remote.RemoteWebDriver.startSession(RemoteWebDriver.java:244)
at org.openqa.selenium.remote.RemoteWebDriver.<init>(RemoteWebDriver.java:131)
at org.openqa.selenium.remote.RemoteWebDriver.<init>(RemoteWebDriver.java:144)
at org.openqa.selenium.chrome.ChromeDriver.<init>(ChromeDriver.java:178)
at org.openqa.selenium.chrome.ChromeDriver.<init>(ChromeDriver.java:167)
at org.openqa.selenium.chrome.ChromeDriver.<init>(ChromeDriver.java:124)
at ChromWebdriverWindows.main(ChromWebdriverWindows.java:10)
Caused by: java.net.SocketException: Connection reset
at java.net.SocketInputStream.read(Unknown Source)
at java.net.SocketInputStream.read(Unknown Source)
at org.apache.http.impl.io.SessionInputBufferImpl.streamRead(SessionInputBufferImpl.java:139)
at org.apache.http.impl.io.SessionInputBufferImpl.fillBuffer(SessionInputBufferImpl.java:155)
at org.apache.http.impl.io.SessionInputBufferImpl.readLine(SessionInputBufferImpl.java:284)
at org.apache.http.impl.conn.DefaultHttpResponseParser.parseHead(DefaultHttpResponseParser.java:140)
at org.apache.http.impl.conn.DefaultHttpResponseParser.parseHead(DefaultHttpResponseParser.java:57)
at org.apache.http.impl.io.AbstractMessageParser.parse(AbstractMessageParser.java:261)
at org.apache.http.impl.DefaultBHttpClientConnection.receiveResponseHeader(DefaultBHttpClientConnection.java:165)
at org.apache.http.impl.conn.CPoolProxy.receiveResponseHeader(CPoolProxy.java:167)
at org.apache.http.protocol.HttpRequestExecutor.doReceiveResponse(HttpRequestExecutor.java:272)
at org.apache.http.protocol.HttpRequestExecutor.execute(HttpRequestExecutor.java:124)
at org.apache.http.impl.execchain.MainClientExec.execute(MainClientExec.java:271)
at org.apache.http.impl.execchain.ProtocolExec.execute(ProtocolExec.java:184)
at org.apache.http.impl.execchain.RetryExec.execute(RetryExec.java:88)
at org.apache.http.impl.execchain.RedirectExec.execute(RedirectExec.java:110)
at org.apache.http.impl.client.InternalHttpClient.doExecute(InternalHttpClient.java:184)
at org.apache.http.impl.client.CloseableHttpClient.execute(CloseableHttpClient.java:71)
at org.apache.http.impl.client.CloseableHttpClient.execute(CloseableHttpClient.java:55)
at org.openqa.selenium.remote.internal.ApacheHttpClient.fallBackExecute(ApacheHttpClient.java:142)
at org.openqa.selenium.remote.internal.ApacheHttpClient.execute(ApacheHttpClient.java:88)
at org.openqa.selenium.remote.ProtocolHandshake.createSession(ProtocolHandshake.java:296)
at org.openqa.selenium.remote.ProtocolHandshake.createSession(ProtocolHandshake.java:113)
at org.openqa.selenium.remote.HttpCommandExecutor.execute(HttpCommandExecutor.java:141)
at org.openqa.selenium.remote.service.DriverCommandExecutor.execute(DriverCommandExecutor.java:82)
... 8 more
Your code looks fine just replace .getProperty() with .setProperty():
System.getProperty("webdriver.chrome.driver",
"C:\\Automation\\chromedriver_win32\\chromedriver.exe");
with
System.setProperty("webdriver.chrome.driver",
"C:\\Automation\\chromedriver_win32\\chromedriver.exe");

How to safely update chromedriver on selenium nodes

I have a selenium grid setup with one hub and 5 nodes. they both use the same version of selenium server 2.41.0.
On the nodes there are already chromedriver setup in the same folder as selenium sever.
Now the task is to update the chromedriver without broken any existing jenkins tests.
I have tried manually go to each nodes and update the chromedriver file. But, the tests on jenkins will throw WebDriverException saying unable to create driver.
What could be the issue here?
Build info: version: '2.41.0', revision: '3192d8a', time: '2014-03-27 17:17:32'
System info: host: 'dseleniumnode05.xxx-dev.com', ip: 'xx.xx.xx.xxx', os.name: 'Linux', os.arch: 'amd64', os.version: '3.11.10-100.fc18.x86_64', java.version: '1.7.0_45'
Driver info: org.openqa.selenium.chrome.ChromeDriver
14:08:37.077 INFO - Executing: [new session: Capabilities [{platform=LINUX, browserName=chrome, proxy={socksUsername=null, noProxy=null, httpProxy=proxy.xxx-stage.com:80, socksPassword=null, ftpProxy=null, sslProxy=proxy.xxx-stage.com:443, proxyAutoconfigUrl=null, proxyType=MANUAL, class=org.openqa.selenium.Proxy, autodetect=false, hCode=1182650898, socksProxy=null}, version=, chrome.switches=[--start-maximized]}]] at URL: /session)
14:08:37.078 INFO - Creating a new session for Capabilities [{platform=LINUX, browserName=chrome, proxy={socksUsername=null, noProxy=null, httpProxy=proxy.xxx-stage.com:80, socksPassword=null, ftpProxy=null, sslProxy=proxy.xxx-stage.com:443, proxyAutoconfigUrl=null, proxyType=MANUAL, class=org.openqa.selenium.Proxy, autodetect=false, hCode=1182650898, socksProxy=null}, version=, chrome.switches=[--start-maximized]}]
Starting ChromeDriver (v2.10.267518) on port 13326
Only local connections are allowed.
[0.500][WARNING]: PAC support disabled because there is no system implementation
14:09:38.101 WARN - Exception thrown
java.util.concurrent.ExecutionException: org.openqa.selenium.WebDriverException: java.lang.reflect.InvocationTargetException
Build info: version: '2.41.0', revision: '3192d8a', time: '2014-03-27 17:17:32'
System info: host: 'dseleniumnode05.xxx-dev.com', ip: 'xx.xx.xx.xxx', os.name: 'Linux', os.arch: 'amd64', os.version: '3.11.10-100.fc18.x86_64', java.version: '1.7.0_45'
Driver info: driver.version: unknown
at java.util.concurrent.FutureTask.report(FutureTask.java:122)
at java.util.concurrent.FutureTask.get(FutureTask.java:188)
at org.openqa.selenium.remote.server.DefaultSession.execute(DefaultSession.java:177)
at org.openqa.selenium.remote.server.DefaultSession.<init>(DefaultSession.java:113)
at org.openqa.selenium.remote.server.DefaultSession.createSession(DefaultSession.java:90)
at org.openqa.selenium.remote.server.DefaultDriverSessions.newSession(DefaultDriverSessions.java:96)
at org.openqa.selenium.remote.server.handler.NewSession.handle(NewSession.java:63)
at org.openqa.selenium.remote.server.rest.ResultConfig.handle(ResultConfig.java:202)
at org.openqa.selenium.remote.server.JsonHttpRemoteConfig.handleRequest(JsonHttpRemoteConfig.java:193)
at org.openqa.selenium.remote.server.DriverServlet.handleRequest(DriverServlet.java:174)
at org.openqa.selenium.remote.server.DriverServlet.doPost(DriverServlet.java:140)
at javax.servlet.http.HttpServlet.service(HttpServlet.java:727)
at org.openqa.selenium.remote.server.DriverServlet.service(DriverServlet.java:112)
at javax.servlet.http.HttpServlet.service(HttpServlet.java:820)
at org.openqa.jetty.jetty.servlet.ServletHolder.handle(ServletHolder.java:428)
at org.openqa.jetty.jetty.servlet.ServletHandler.dispatch(ServletHandler.java:680)
at org.openqa.jetty.jetty.servlet.ServletHandler.handle(ServletHandler.java:571)
at org.openqa.jetty.http.HttpContext.handle(HttpContext.java:1526)
at org.openqa.jetty.http.HttpContext.handle(HttpContext.java:1479)
at org.openqa.jetty.http.HttpServer.service(HttpServer.java:920)
at org.openqa.jetty.http.HttpConnection.service(HttpConnection.java:820)
at org.openqa.jetty.http.HttpConnection.handleNext(HttpConnection.java:986)
at org.openqa.jetty.http.HttpConnection.handle(HttpConnection.java:837)
at org.openqa.jetty.http.SocketListener.handleConnection(SocketListener.java:243)
at org.openqa.jetty.util.ThreadedServer.handle(ThreadedServer.java:358)
at org.openqa.jetty.util.ThreadPool$PoolThread.run(ThreadPool.java:537)
Caused by: org.openqa.selenium.WebDriverException: java.lang.reflect.InvocationTargetException
Build info: version: '2.41.0', revision: '3192d8a', time: '2014-03-27 17:17:32'
System info: host: 'dseleniumnode05.xxx-dev.com', ip: 'xx.xx.xx.xxx', os.name: 'Linux', os.arch: 'amd64', os.version: '3.11.10-100.fc18.x86_64', java.version: '1.7.0_45'
Driver info: driver.version: unknown
at org.openqa.selenium.remote.server.DefaultDriverFactory.callConstructor(DefaultDriverFactory.java:72)
at org.openqa.selenium.remote.server.DefaultDriverFactory.newInstance(DefaultDriverFactory.java:56)
at org.openqa.selenium.remote.server.DefaultSession$BrowserCreator.call(DefaultSession.java:216)
at org.openqa.selenium.remote.server.DefaultSession$BrowserCreator.call(DefaultSession.java:1)
at java.util.concurrent.FutureTask.run(FutureTask.java:262)
at org.openqa.selenium.remote.server.DefaultSession$1.run(DefaultSession.java:170)
at java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1145)
at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:615)
at java.lang.Thread.run(Thread.java:744)
Caused by: java.lang.reflect.InvocationTargetException
at sun.reflect.NativeConstructorAccessorImpl.newInstance0(Native Method)
at sun.reflect.NativeConstructorAccessorImpl.newInstance(NativeConstructorAccessorImpl.java:57)
at sun.reflect.DelegatingConstructorAccessorImpl.newInstance(DelegatingConstructorAccessorImpl.java:45)
at java.lang.reflect.Constructor.newInstance(Constructor.java:526)
at org.openqa.selenium.remote.server.DefaultDriverFactory.callConstructor(DefaultDriverFactory.java:62)
... 8 more
Caused by: org.openqa.selenium.WebDriverException: unknown error: Chrome failed to start: exited abnormally
(Driver info: chromedriver=2.10.267518,platform=Linux 3.11.10-100.fc18.x86_64 x86_64) (WARNING: The server did not provide any stacktrace information)
Command duration or timeout: 60.52 seconds
Build info: version: '2.41.0', revision: '3192d8a', time: '2014-03-27 17:17:32'
System info: host: 'dseleniumnode05.xxx-dev.com', ip: 'xx.xx.xx.xxx', os.name: 'Linux', os.arch: 'amd64', os.version: '3.11.10-100.fc18.x86_64', java.version: '1.7.0_45'
Driver info: org.openqa.selenium.chrome.ChromeDriver
at sun.reflect.NativeConstructorAccessorImpl.newInstance0(Native Method)
at sun.reflect.NativeConstructorAccessorImpl.newInstance(NativeConstructorAccessorImpl.java:57)
at sun.reflect.DelegatingConstructorAccessorImpl.newInstance(DelegatingConstructorAccessorImpl.java:45)
at java.lang.reflect.Constructor.newInstance(Constructor.java:526)
at org.openqa.selenium.remote.ErrorHandler.createThrowable(ErrorHandler.java:193)
at org.openqa.selenium.remote.ErrorHandler.throwIfResponseFailed(ErrorHandler.java:145)
at org.openqa.selenium.remote.RemoteWebDriver.execute(RemoteWebDriver.java:595)
at org.openqa.selenium.remote.RemoteWebDriver.startSession(RemoteWebDriver.java:240)
at org.openqa.selenium.chrome.ChromeDriver.startSession(ChromeDriver.java:181)
at org.openqa.selenium.remote.RemoteWebDriver.<init>(RemoteWebDriver.java:126)
at org.openqa.selenium.remote.RemoteWebDriver.<init>(RemoteWebDriver.java:139)
at org.openqa.selenium.chrome.ChromeDriver.<init>(ChromeDriver.java:160)
at org.openqa.selenium.chrome.ChromeDriver.<init>(ChromeDriver.java:128)
... 13 more
14:09:38.103 WARN - Exception: unknown error: Chrome failed to start: exited abnormally
(Driver info: chromedriver=2.10.267518,platform=Linux 3.11.10-100.fc18.x86_64 x86_64) (WARNING: The server did not provide any stacktrace information)
Command duration or timeout: 60.52 seconds
the matter is that instance of driver is created on host machine (using existing chromdriver file there). Obviously once you substitute updated chrome driver file (of a newer version) older one -> everything should work fine after driver instance reinitizalization.
To initialize driver , I'm using following java piece of code:
public static WebDriver driverSetUp(WebDriver driver) throws MalformedURLException {
DesiredCapabilities capability = DesiredCapabilities.chrome();
log.info("Google chrome is selected");
System.setProperty("webdriver.chrome.driver", "....path/chromedriver.exe");
capability.setBrowserName("chrome");
capability.setPlatform(org.openqa.selenium.Platform.WINDOWS);
String webDriverURL = "http://" + environmentData.getHubIP() + ":" + environmentData.getHubPort() + "/wd/hub";
driver = new RemoteWebDriver(new URL(webDriverURL), capability);
driver.manage().timeouts().implicitlyWait(20, TimeUnit.SECONDS);
driver.manage().timeouts().pageLoadTimeout(30, TimeUnit.SECONDS);
driver.manage().window().setSize(new Dimension(1920, 1080));
return driver;
}
Try it out and let us know whether issue persists. Thanks.

Query related to Explicit wait: wait.until(ExpectedConditions.visibilityOfElementLocated(By.id(

package wait1;
import org.openqa.selenium.By;
import org.openqa.selenium.firefox.FirefoxDriver;
import org.openqa.selenium.support.ui.ExpectedConditions;
import org.openqa.selenium.support.ui.WebDriverWait;
public class Explicit {
public static void main(String[] args) {
FirefoxDriver driver= new FirefoxDriver();
WebDriverWait wait= new WebDriverWait(driver,20 );
driver.get("http://www.91mobiles.com/");
driver.findElement(By.xpath("//*[#id='q']")).sendKeys("Micromax");
//wait.until(ExpectedConditions.visibilityOfElementLocated(By.xpath("//*[#id='ui-id-22']/span[2]")));
wait.until(ExpectedConditions.visibilityOfElementLocated(By.id("id=ui-id-172")));
driver.findElement(By.xpath("//*[#id='ui-id-52']")).click();
}
}
I am getting the following error when I execute the above script:
Exception in thread "main" org.openqa.selenium.TimeoutException: Timed out after 20 seconds waiting for visibility of element located by By.id: id=ui-id-172
Build info: version: '2.33.0', revision: '4e90c97', time: '2013-05-22 15:33:32'
System info: os.name: 'Windows 7', os.arch: 'amd64', os.version: '6.1', java.version: '1.7.0_25'
Driver info: driver.version: unknown
at org.openqa.selenium.support.ui.FluentWait.timeoutException(FluentWait.java:259)
at org.openqa.selenium.support.ui.FluentWait.until(FluentWait.java:228)
at wait1.Explicit.main(Explicit.java:20)
Caused by: org.openqa.selenium.NoSuchElementException: Unable to locate element: {"method":"id","selector":"id=ui-id-172"}
Command duration or timeout: 21 milliseconds
For documentation on this error, please visit: http://seleniumhq.org/exceptions/no_such_element.html
Build info: version: '2.33.0', revision: '4e90c97', time: '2013-05-22 15:33:32'
System info: os.name: 'Windows 7', os.arch: 'amd64', os.version: '6.1', java.version: '1.7.0_25'
Session ID: fd977506-2457-4981-a304-f9a9b6b57f4e
Driver info: org.openqa.selenium.firefox.FirefoxDriver
Capabilities [{platform=XP, databaseEnabled=true, cssSelectorsEnabled=true, javascriptEnabled=true, acceptSslCerts=true, handlesAlerts=true, browserName=firefox, browserConnectionEnabled=true, nativeEvents=true, webStorageEnabled=true, rotatable=false, locationContextEnabled=true, applicationCacheEnabled=true, takesScreenshot=true, version=17.0.7}]
at sun.reflect.GeneratedConstructorAccessor10.newInstance(Unknown Source)
at sun.reflect.DelegatingConstructorAccessorImpl.newInstance(Unknown Source)
at java.lang.reflect.Constructor.newInstance(Unknown Source)
at org.openqa.selenium.remote.ErrorHandler.createThrowable(ErrorHandler.java:191)
at org.openqa.selenium.remote.ErrorHandler.throwIfResponseFailed(ErrorHandler.java:145)
at org.openqa.selenium.remote.RemoteWebDriver.execute(RemoteWebDriver.java:554)
at org.openqa.selenium.remote.RemoteWebDriver.findElement(RemoteWebDriver.java:307)
at org.openqa.selenium.remote.RemoteWebDriver.findElementById(RemoteWebDriver.java:348)
at org.openqa.selenium.By$ById.findElement(By.java:216)
at org.openqa.selenium.remote.RemoteWebDriver.findElement(RemoteWebDriver.java:299)
at org.openqa.selenium.support.ui.ExpectedConditions.findElement(ExpectedConditions.java:522)
at org.openqa.selenium.support.ui.ExpectedConditions.access$0(ExpectedConditions.java:520)
at org.openqa.selenium.support.ui.ExpectedConditions$4.apply(ExpectedConditions.java:130)
at org.openqa.selenium.support.ui.ExpectedConditions$4.apply(ExpectedConditions.java:1)
at org.openqa.selenium.support.ui.FluentWait.until(FluentWait.java:208)
... 1 more
Caused by: org.openqa.selenium.remote.ErrorHandler$UnknownServerException: Unable to locate element: {"method":"id","selector":"id=ui-id-172"}
Build info: version: '2.33.0', revision: '4e90c97', time: '2013-05-22 15:33:32'
System info: os.name: 'Windows 7', os.arch: 'amd64', os.version: '6.1', java.version: '1.7.0_25'
Driver info: driver.version: unknown
The behavior you are getting is the expected bahavior. You specified a 20 second explicit wait and in that time the ExpectedConditions.visibilityOfElementLocated(...) could not be established. So the wait fails with a timeout.
If you want to go on in your program you need to surround the wait in a try-catch block and catch org.openqa.selenium.TimeoutException
Try using like this
wait.until(ExpectedConditions.visibilityOfElementLocated(By.xpath("//*[#id='ui-id-52']"));
Make sure that whatever identification type you use while waiting should be in the statement you use for action. (e.g. click, set etc.)
Here, we have two solutions...
Try increasing your WebDriverWait time to check if it fix the issue.
Try to locate same element by firebug, if it is successfully found by firebug, than WebDriverWait time is the only culprit.
You'll always get a timeout with the code you have. This is the offending line:
wait.until(ExpectedConditions.visibilityOfElementLocated(By.id("id=ui-id-172")));
Note how you have By.id("id=ui-id-172"). This is wrong. It would look for an object that has the id id=ui-id-172. While it is possible to have an id with this value (yes, I tried and it works) it is unlikely that this is what you want, especially given your XPath expression on the next line. What you want, to be consistent with the rest of your code, is By.id("ui-id-172").