Getting "Connection is not recognized as a valid connection manager type" error in SSIS 2008 R2, but package runs fine - sql

One of my primary SSIS import packages has been showing the following error the last few times it's been run. The data loads exactly how it should, just with this one error which doesn't seem to make a real difference. I would like to get it cleared up though.
Here is the error:
Error 1 Error loading Update.dtsx: The connection type "OLEDB" specified for connection manager "SQL.Staging" is not recognized as a valid connection manager type. This error is returned when an attempt is made to create a connection manager for an unknown connection type. Check the spelling in the connection type name. D:\SSIS Projects\Update.dtsx 1 1
Error 2 Error loading Update.dtsx: Error loading value " 0 SQL.Staging {925404E7-27AA-4C4E-337B-D6058341" from node "DTS:ConnectionManager". D:\SSIS Projects\Update.dtsx 1 1
Error 3 Error loading 'Update.dtsx' : The package failed to load due to error 0xC0010014 "One or more error occurred. There should be more specific errors preceding this one that explains the details of the errors. This message is used as a return value from functions that encounter errors.". This occurs when CPackage::LoadFromXML fails. . D:\SSIS Projects\Update.dtsx 1 1
As I said, the package runs fine. It doesn't seem to have any issues with the OLEDB source or destination's, which is what the error seems to indicate. Any other recommendations? Thanks!

Related

How do I solve "-307" error on ZKTeco SDK?

Hello everyone and thanks for reading this problem.
I have a solution in C# using the zkemkeeper dll to get the records from some access control devices. When I "ping" them, there isn't any problem, but when I try to connect to them (Using my solution or the standalone demo to get attendance) I get the "-307" error with the "Unable to connect message". That's not very clear and I would really aprecciate if someone can explain what this error is (please!!!!). I would really like to understand these errors myself, so, where can I find all the definition of these errors?
In short:
1.- What is the problem regarding the "-307" error?
2.- Is there any place where all these errors are documented?
Thanks in advance!!
enter image description here
maybe you should check your device, you can ping them
Attention
The dwErrorCode parameter specifies the error code. The values are described as follows:
During connection, the following error codes may be returned:
0 Connected successfully
-1 Failed to invoke the interface
-2 Failed to initialize
-3 Failed to initialize parameters
-5 Data mode read error
-6 Wrong password
-7 Reply error
-8 Receive timeout
-307 Connection timeout
In invoking other interfaces, the following error codes may be returned:
-201 Device is busy
-199 New Mode
-103 device send back error of face version error
-102 face template version error, like 8.0 face template send to 7.0 device
-101 malloc memory failed
-100 Not supported or the data does not exist
-10 The length of transmitted data is incorrect
-5 Data already exists
-4 Insufficient space
-3 Wrong size
-2 File read/write error
-1 The SDK is not initialized and needs to be reconnected
0 Data not found or duplicate data
1 Correct operation
4 Parameter error
101 Buffer allocation error
102 repeat invoking
Underlying error codes:
-12001 Socket creation timeout (connection timeout)
-12002 Insufficient memory
-12003 Wrong Socket version
-12004 Not TCP protocol
-12005 Waiting timeout
-12006 Data transmission timeout
-12007 Data reading timeout
-12008 Failed to read Socket
-13009 Waiting event error
-13010 Exceeded retry attempts
-13011 Wrong reply ID
-13012 Checksum error
-13013 Waiting event timeout
-13014 DIRTY_DATA
-13015 Buffer size too small
-13016 Wrong data length
-13017 Invalid data read1
-13018 Invalid data read2
-13019 Invalid data read3
-13020 Data loss
-13021 Memory initialization error
-15001 Invoking return value of status key issued by SetShortkey interface repeatedly
-15002 Invoking return value of description issued by SetShortkey interface repeatedly
-15003 The two level menu is not opened in the device, and the data need not be issued
getdevicedata and setdevicedata invocation error codes
-15100 Error occurs in obtaining table structure
-15101 The condition field does not exist in the table structure
-15102 Inconsistency in the total number of fields
-15103 Inconsistency in sorting fields
-15104 Memory allocation error
-15105 Data parsing error
-15106 Data overflow as the transmitted data exceeds 4M
-15108 Invalid options
-15113 Data parsing error: table ID not found
-15114 A data exception is returned as the number of fields is smaller than or equal to 0
-15115 A data exception is returned as the total number of table fields is inconsistent with the
total number of fields of the data
Firmware error codes:
2000 Return OK to execute
-2001 Return Fail to execute command
-2002 Return Data
-2003 Regstered event occorred
-2004 Return REPEAT Command
-2005 Return UNAUTH Command
0xffff Return Unknown Command
-4999 Device parameter read error
-4998 Device parameter write error
-4997 The length of the data sent by the software to the device is incorrect
228
229
-4996 A parameter error exists in the data sent by the software to the device
-4995 Failed to add data to the database
-4994 Failed to update the database
-4993 Failed to read data from the database
-4992 Failed to delete data in the database
-4991 Data not found in the database
-4990 The data amount in the database reaches the limit
-4989 Failed to allocate memory to a session
-4988 Insufficient space in the memory allocated to a session
-4987 The memory allocated to a session overflows
-4986 File does not exist
-4985 File read failure
-4984 File write failure
-4983 Failed to calculate the hash value
-4982 Failed to allocate memory
Note
This interface is applicable to the new architecture firmware.

Runtime error : DBSQL_SQL_ERROR exception : CX_SY_OPEN_SQL_DB, where to focus?

More info from stms :
Short Text
SQL error "SQL code: -10108" occurred while accessing table "CDHDR".
What happened?
Database error text: "SQL message: Session has been reconnected."
Return value of the database layer: "SQL dbsl rc: 99"
The problem is that client is running this code through the job in which I am not available to debug it. All I know is that it is working for other countries selected but for some specific it is not so the question is :
Was it a temporary connection error between two servers or is it data overload issue due to SELECT statement?
At the moment I am not really sure which thing I have to look on the system, the same program once produced the error for exceeding the limit in the db query ( > 10 minutes) so this might be related to system configuration or what?
Thanks in advance

failed to connect to a database in B1if

sometimes i have this error when i try to connect to my database in B1if :
vBIU.errhdlg='' exceptionmsg='com.sap.b1i.xcellerator.XcelleratorException: XCE001 Nested exception:
com.sap.b1i.bizprocessor.BizProcException: BPE001 Nested exception:
com.sap.b1i.xcellerator.XcelleratorException: XCE001 Nested exception:
com.sap.b1i.xcellerator.XcelleratorException: XCE001 Nested exception: java.lang.RuntimeException: Connect to
Business One failed. (-119) Database server type not supported -b1Server=SRV-B1-HYPPROD,
company=SBO_HYPFR_PROD, licenseServer=HYP-B1-LIC:30000, dbType=7, dbUser=sa, userName=B1i-' msglogexcl='false'
handover2CentralSrv='' MessageLog='true' msglogdbop='insert'>
the question is how to fix that ?
The Error happens when B1i don't get a connection to the DB. That should not be a problem because B1i repeats the process after a minuten and then the connection should be there.
We fixed this by Installing the 64 Bit version of B1DIAPI.x64. Not sure why that worked.
Note you need to update the SLD links for your database and SBO-COMMON - the jcoPath will likely be different - replace the "Program Files (x86)" with just "Program Files".

SSIS Excel Source error: [Excel Source [1]] Error: SSIS Error Code DTS_E_OLEDBERROR. An OLE DB error has occurred. Error code: 0x80004005

I have a very simple SSIS Data Flow that Unions two Excel Sources together, does a small data conversion, and loads into a staging table.
However, my two Excel Sources are failing immediately as the Execute Phase begins.
I am only receiving the following nondescript errors:
[LA Report Source [627]] Error: SSIS Error Code DTS_E_OLEDBERROR. An OLE DB error has occurred. Error code: 0x80004005.
[SSIS.Pipeline] Error: SSIS Error Code DTS_E_PRIMEOUTPUTFAILED. The PrimeOutput method on component "LA Report Source" (627) returned error code 0xC0202009. The component returned a failure code when the pipeline engine called PrimeOutput(). The meaning of the failure code is defined by the component, but the error is fatal and the pipeline stopped executing. There may be error messages posted before this with more information about the failure.
[NOLA Report Source [640]] Error: SSIS Error Code DTS_E_OLEDBERROR. An OLE DB error has occurred. Error code: 0x80004005.
[SSIS.Pipeline] Error: SSIS Error Code DTS_E_PRIMEOUTPUTFAILED. The PrimeOutput method on component "NOLA Report Source" (640) returned error code 0xC0202009. The component returned a failure code when the pipeline engine called PrimeOutput(). The meaning of the failure code is defined by the component, but the error is fatal and the pipeline stopped executing. There may be error messages posted before this with more information about the failure.
This package had been working for several days, and suddenly started giving this error message a couple days ago, with no real changes to the data source.
In addition, when I go to preview the Excel Data Source, I get this weird error:
Any ideas? Using Visual Studio 2008.
I want to share the solution I came up with:
I was over-zealous with my SQL Query in the Excel Source. I had a WHERE filter on my select statement, which worked for a little while, but an anomaly in the data must have thrown something off - SSIS didn't like it at all.
I've removed the WHERE portion, just leaving the SELECT portion, and I've handled the filter with a Conditional Split instead. Problem solved!

SSAS Process Dimensions Error

I'm trying to deploy my SSAS project but I keep getting this error that makes no sense to me?
Error 5 Internal error: The operation terminated unsuccessfully. 0 0
Error 6 The datasource, 'Adventure Works DW2012', contains an ImpersonationMode that is not supported for processing operations. 0 0
Error 7 Errors in the high-level relational engine. A connection could not be made to the data source with the DataSourceID of 'Adventure Works DW2012', Name of 'Adventure Works DW2012'. 0 0
Error 8 Errors in the OLAP storage engine: An error occurred while the dimension, with the ID of 'Dim Organization', Name of 'Dim Organization' was being processed. 0 0
Error 9 Errors in the OLAP storage engine: An error occurred while the 'Organization Name' attribute of the 'Dim Organization' dimension from the 'CubeDemo06' database was being processed. 0 0
Error 10 Server: The current operation was cancelled because another operation in the transaction failed. 0 0
Maybe the "ImpersonationMode" has to do with login credentials? I'm using "use current user", maybe that could be the problem? How do you change that now? The other errors are strange since everything should work according to this tutorial: https://www.accelebrate.com/library/tutorials/ssas-2008
Problem solved by using Windows Credentials!
Go to the data source and select service account option as below