Related
This is the source of the original VBA code: Original VBA code
Im converting these functions to VB.Net
FilePropertyExplorer
Class_Initialize
Heres the code I have thus far (note I removed some lines for brevity)
Imports System.Runtime.InteropServices
Public Class VirtualCOMObject
Private Const OPTION_BASE As Long = 0
Private Const OPTION_FLAGS As Long = 2
Private Const OPTION_INCLUDE_REFERENCEDOCS As Long = 0
Private Const OPTION_DISABLEDCLASSES As String = ""
Private Const DECOMPRESSED_EXT As Long = 56493
Private Const SIZEOF_PTR32 As Long = &H4
Private Const SIZEOF_PTR64 As Long = &H8
Private Const PAGE_EXECUTE_RW As Long = &H40
Private Const MEM_RESERVE_AND_COMMIT As Long = &H3000
Private Const ERR_OUT_OF_MEMORY As Long = &H7
Private m_ClassFactory As Object
<DllImport("kernel32.dll", CharSet:=CharSet.None, ExactSpelling:=False, SetLastError:=True)>
Private Shared Function VirtualAlloc(
ByVal lpAddress As IntPtr,
ByVal dwSize As UIntPtr,
ByVal flAllocationType As AllocationType,
ByVal flProtect As MemoryProtection) As IntPtr
End Function
<DllImport("kernel32.dll", CharSet:=CharSet.Auto, SetLastError:=True)>
Public Shared Function GetModuleHandleA(ByVal lpModuleName As String) As IntPtr
End Function
<DllImport("kernel32.dll", SetLastError:=True, CharSet:=CharSet.Ansi, ExactSpelling:=True)>
Public Shared Function GetProcAddress(ByVal hModule As IntPtr, ByVal procName As String) As IntPtr
End Function
<DllImport("kernel32.dll", SetLastError:=True, CharSet:=CharSet.Ansi, ExactSpelling:=True, EntryPoint:="RtlMoveMemory")>
Public Shared Sub CopyMemoryAnsi(ByVal Dest As IntPtr, ByVal Source As String, ByVal Size As IntPtr)
End Sub
<DllImport("kernel32.dll", SetLastError:=True, CharSet:=CharSet.Ansi, ExactSpelling:=True, EntryPoint:="RtlMoveMemory")>
Public Shared Sub CastToObject(ByRef Dest As Object, ByRef Source As IntPtr, ByVal Size As IntPtr)
End Sub
Declare Sub CopyMemoryByref Lib "Kernel32.dll" Alias "RtlMoveMemory" (ByRef dest As Integer, ByRef source As Integer, ByVal numBytes As Integer)
<Flags>
Public Enum AllocationType As UInteger
COMMIT = 4096
RESERVE = 8192
RESET = 524288
TOP_DOWN = 1048576
WRITE_WATCH = 2097152
PHYSICAL = 4194304
LARGE_PAGES = 536870912
End Enum
<Flags>
Public Enum MemoryProtection As UInteger
NOACCESS = 1
[READONLY] = 2
READWRITE = 4
WRITECOPY = 8
EXECUTE = 16
EXECUTE_READ = 32
EXECUTE_READWRITE = 64
EXECUTE_WRITECOPY = 128
GUARD_Modifierflag = 256
NOCACHE_Modifierflag = 512
WRITECOMBINE_Modifierflag = 1024
End Enum
Public Sub Class_Initialize()
Dim NativeCode As String
Dim LoaderVTable As IDispatchVTable
Dim Ignore As Boolean
Dim ClassFactoryLoader As Object
#If VBA7 = False Then
Dim Kernel32Handle As Long
Dim GetProcAddressPtr As Long
Dim NativeCodeAddr As Long
Dim LoaderVTablePtr As Long
Dim LoaderObj As Long
#Else
Dim Kernel32Handle As LongPtr
Dim GetProcAddressPtr As LongPtr
Dim NativeCodeAddr As LongPtr
Dim LoaderVTablePtr As LongPtr
Dim LoaderObj As LongPtr
#End If
'#If Win64 = False Then
' Const SIZEOF_PTR = SIZEOF_PTR32
'#Else
Const SIZEOF_PTR = SIZEOF_PTR64
'#End If
'NativeCode string initialized here
NativeCode = NativeCode & "%EEEE%::::RPZPPPh$#$$j PPPPH+T$ t5AYAZkDTX 5j7{{L3TQ#M3LR#A)DR#Xf5##fA)AUXI3DR#ZZZZZZ?!, #RY3LDl3TA#PY,VH)DJ#XXXXXXXXXX%EEEE%::::VSPPPPj PPPPPPPP4T)D$04P)D$,4 '4 )D$($ PZ3D$#+D$ YQ3H +L$ XP3Q +T$0XPf55nf)BUR[YQ^VXP2Cf<0tF1+++
'==========================================================================
'Code removed for brevity. The full string can be found on the links above
'==========================================================================
ij DdEXXZPEdkHOqrLSKGZT;pOCUHvFst;z??qapyyZtzrUuhX_;hnJmp;n;kGQF^AF oqvSDDS\^;TufXPumRLDVQSzCbT]x]keCb?fWgTwFvTwEj0"
ClassFactoryLoader = New Object()
' Allocate the executable memory for the object
NativeCodeAddr = VirtualAlloc(0, Len(NativeCode) + DECOMPRESSED_EXT, MEM_RESERVE_AND_COMMIT, PAGE_EXECUTE_RW)
If NativeCodeAddr <> 0 Then
' Copy the x86 and x64 native code into the allocated memory
Call CopyMemoryAnsi(NativeCodeAddr, NativeCode, Len(NativeCode))
' Force the memory address into an Object variable (also triggers the shell code)
LoaderVTable.QueryInterface = NativeCodeAddr 'longptr
LoaderVTablePtr = VarPtr(LoaderVTable) 'ptr to LoaderVTable(IDispatchVTable structure)
LoaderObj = VarPtr(LoaderVTablePtr)
'==========================================================================
'ERROR: Managed Debugging Assistant 'InvalidVariant' : 'An invalid VARIANT was detected during a conversion from an unmanaged VARIANT to a managed object. Passing invalid VARIANTs to the CLR can cause unexpected exceptions, corruption or data loss.'
'==========================================================================
Call CastToObject(ClassFactoryLoader, LoaderObj, SIZEOF_PTR) 'CastToObject=RtlMoveMemory
Ignore = TypeOf ClassFactoryLoader Is VBA.Collection 'ClassFactoryLoader(object type)
m_ClassFactory = (ClassFactoryLoader) 'object
' Initialize our COM object
Kernel32Handle = GetModuleHandleA("kernel32")
GetProcAddressPtr = GetProcAddress(Kernel32Handle, "GetProcAddress")
'With m_ClassFactory
' Call .Init(Kernel32Handle, GetProcAddressPtr, OPTION_BASE + OPTION_FLAGS, NativeCode, New FilePropertyExplorer_Helper)
' Ignore = TypeOf .FileProperties Is FileProperties And TypeOf .FileProperty Is FileProperty
'End With
Else
Err.Raise(ERR_OUT_OF_MEMORY)
End If
End Sub
Function OpenFile(ByVal FilePath As String, Optional ByVal WriteSupport As Boolean = False) As FileProperties
OpenFile = m_ClassFactory.OpenFile(FilePath, WriteSupport)
End Function
End Class
<StructLayout(LayoutKind.Sequential, CharSet:=CharSet.Ansi, Pack:=1)>
Public Structure IDispatchVTable
Public QueryInterface As IntPtr
Public AddRef As IntPtr
Public Release As IntPtr
Public GetTypeInfoCount As IntPtr
Public GetTypeInfo As IntPtr
Public GetIDsOfNames As IntPtr
Public Invoke As IntPtr
End Structure
VarToPtr . Im unsure of this code. Found it on the internet and slightly modified it
Module VarPtrSupport
' a delegate that can point to the VarPtrCallback method
Private Delegate Function VarPtrCallbackDelegate(
ByVal address As Integer, ByVal unused1 As Integer,
ByVal unused2 As Integer, ByVal unused3 As Integer) As Integer
' two aliases for the CallWindowProcA Windows API method
' notice that 2nd argument is passed by-reference
Private Declare Function CallWindowProc Lib "user32" _
Alias "CallWindowProcA" _
(ByVal wndProc As VarPtrCallbackDelegate, ByRef var As Short,
ByVal unused1 As Integer, ByVal unused2 As Integer,
ByVal unused3 As Integer) As Integer
Private Declare Function CallWindowProc Lib "user32" _
Alias "CallWindowProcA" _
(ByVal wndProc As VarPtrCallbackDelegate, ByRef var As Integer,
ByVal unused1 As Integer, ByVal unused2 As Integer,
ByVal unused3 As Integer) As Integer
' ...add more overload to support other data types...
Private Declare Function CallWindowProc Lib "user32" _
Alias "CallWindowProcA" _
(ByVal wndProc As VarPtrCallbackDelegate, ByRef var As IDispatchVTable,
ByVal unused1 As Integer, ByVal unused2 As Integer,
ByVal unused3 As Integer) As Integer
Private Declare Function CallWindowProc Lib "user32" _
Alias "CallWindowProcA" _
(ByVal wndProc As VarPtrCallbackDelegate, ByRef var As Long,
ByVal unused1 As Integer, ByVal unused2 As Integer,
ByVal unused3 As Integer) As Integer
Private Declare Function CallWindowProc Lib "user32" _
Alias "CallWindowProcA" _
(ByVal wndProc As VarPtrCallbackDelegate, ByRef var As IntPtr,
ByVal unused1 As Integer, ByVal unused2 As Integer,
ByVal unused3 As Integer) As Integer
' the method that is indirectly executed when calling CallVarPtrSupport
' notice that 1st argument is declared by-value (this is the
' argument that receives the 2nd value passed to CallVarPtrSupport)
Private Function VarPtrCallback(ByVal address As Integer,
ByVal unused1 As Integer, ByVal unused2 As Integer,
ByVal unused3 As Integer) As Integer
Return address
End Function
' two overloads of VarPtr
Public Function VarPtr(ByRef var As Short) As Integer
Return CallWindowProc(AddressOf VarPtrCallback, var, 0, 0, 0)
End Function
Public Function VarPtr(ByRef var As Integer) As Integer
Return CallWindowProc(AddressOf VarPtrCallback, var, 0, 0, 0)
End Function
Public Function VarPtr(ByRef var As IDispatchVTable) As Integer
Return CallWindowProc(AddressOf VarPtrCallback, var, 0, 0, 0)
End Function
Public Function VarPtr(ByRef var As Long) As Integer
Return CallWindowProc(AddressOf VarPtrCallback, var, 0, 0, 0)
End Function
Public Function VarPtr(ByRef var As IntPtr) As Integer
Return CallWindowProc(AddressOf VarPtrCallback, var, 0, 0, 0)
End Function
' ...add more overload to support other data types...
End Module
Now I currently get the error (I placed a comment in the code):
ERROR: Managed Debugging Assistant 'InvalidVariant' : 'An invalid VARIANT was detected during a conversion from an unmanaged VARIANT to a managed object. Passing invalid VARIANTs to the CLR can cause unexpected exceptions, corruption or data loss.'
But overall... Im actually unsure if Im even on the right track in properly converting the VBA code as Im having to do it without for example excel installed to test the VBA out on.
The code essentially creates a dynamic COM object which will then be used to fetch extended file properties.
If someone could perhaps tell me what Im doing wrong it will be appreciated. Also the code needs to be in .Net and not import any VBA/VB dll's.
In reference to #Jimi's comment, I have created a couple of vba functions for you.
Here is the vba Code which you can just paste into an excel "ThisWorkbook" object.
It will create a text file name "ExtendedProperties.txt" in the same directory as the file that is passed to it.
Sub GetExtendedProperties(strInFullFilePath)
Dim objShell As Object
Dim objFolder As Object
Dim objFolderItem As Object
Dim strPath As String
Dim strFldr As String
Dim vntInfo As Variant
Dim intI As Integer
Dim strName As String
Dim strTemp As String
Dim fso As Object
Dim strOut As String
Dim ts As Object
Set fso = CreateObject("Scripting.FileSystemObject")
strPath = fso.GetAbsolutePathName(strInFullFilePath)
strFldr = fso.GetParentFolderName(strPath)
strName = fso.GetFileName(strPath)
strOut = strFldr & "\ExtendedProperties.txt"
Set ts = fso.CreateTextFile(strOut, True)
Set objShell = CreateObject("shell.application")
If (Not (objShell Is Nothing)) Then
Set objFolder = objShell.Namespace(CStr(strFldr))
If (Not (objFolder Is Nothing)) Then
Set objFolderItem = objFolder.ParseName(CStr(strName))
If (Not (objFolderItem Is Nothing)) Then
For intI = 0 To 321
If intI <> 31 Then
vntInfo = objFolder.GetDetailsOf(Nothing, intI)
strTemp = CStr(vntInfo)
If (InStr(1, strTemp, vbNull) > 0) Then strTemp = Replace(strTemp, vbNull, "")
If IsNull(strTemp) = False Then
ts.WriteLine "File Detail Attribute: " & CheckString(strTemp)
Else
ts.WriteLine "File Detail Attribute: NULL"
End If
vntInfo = objFolder.GetDetailsOf(objFolderItem, intI)
strTemp = CStr(vntInfo)
If (InStr(1, strTemp, vbNull) > 0) Then strTemp = Replace(strTemp, vbNull, "")
If IsNull(strTemp) = False Then
ts.WriteLine "Value: """ & CheckString(strTemp) & """"
Else
ts.WriteLine "Value: NULL"
End If
End If
Next intI
End If
Set objFolderItem = Nothing
End If
Set objFolder = Nothing
End If
ts.Close
Set ts = Nothing
Set objShell = Nothing
End Sub
Private Function CheckString(strInString As String) As String
Dim strOut As String
Dim strTemp As String
Dim blnValid As Boolean
Dim intI As Integer
Dim intJ As Integer
Dim strChar As String
Dim bytChars() As Byte
'This Function is used to check the string to see if there are any problem
' characters in the string (as there are at intI=31 in the above function).
strTemp = strInString
strOut = ""
For intI = 1 To Len(strTemp)
strChar = Mid(strTemp, intI, 1)
If (AscW(strChar) = 32) Or (AscW(strChar) >= 48) And (AscW(strChar) <= 57) Or _
(AscW(strChar) >= 65) And (AscW(strChar) <= 90) Or _
(AscW(strChar) >= 97) And (AscW(strChar) <= 122) Then
strOut = strOut & strChar
End If
Next intI
CheckString = strOut
End Function
I can get the Base64 data from a CommandBarButton.Picture by copying it to the Windows Clipboard and saving it to file.
Unfortunately, this process is too slow. It takes about 45 seconds to process the 4676 unique images. Is there a way to get the Base64 data directly from an image in the Windows Clipboard?
Alternately, is there a way to Multithread the process? I am working on running a PowerShell script that will process the clipboard but would rather do it directly from the VBA.
Option Explicit
'Referrence: Stephen Bullen: http://www.oaltd.co.uk
'Open the clipboard to read
Private Declare Function OpenClipboard Lib "user32" (ByVal hwnd As Long) As Long
'Get a pointer to the bitmap/metafile
Private Declare Function GetClipboardData Lib "user32" (ByVal wFormat As Integer) As Long
'Close the clipboard
Private Declare Function CloseClipboard Lib "user32" () As Long
'Convert the handle into an OLE IPicture interface.
Private Declare Function OleCreatePictureIndirect Lib "olepro32.dll" (PicDesc As uPicDesc, RefIID As GUID, ByVal fPictureOwnsHandle As Long, IPic As IPicture) As Long
'Declare a UDT to store a GUID for the IPicture OLE Interface
Private Type GUID: Data1 As Long: Data2 As Integer: Data3 As Integer: Data4(0 To 7) As Byte: End Type
'Declare a UDT to store the bitmap information
Private Type uPicDesc: Size As Long: Type As Long: hPic As Long: hPal As Long: End Type
Private Declare Function GetObject Lib "gdi32" Alias "GetObjectA" (ByVal hObject As Long, ByVal nCount As Long, lpObject As Any) As Long
Private Declare Function GetBitmapBits Lib "gdi32" (ByVal hBitmap As Long, ByVal dwCount As Long, lpBits As Any) As Long
Private Type Bitmap
bmType As Long
bmWidth As Long
bmHeight As Long
bmWidthBytes As Long
bmPlanes As Integer
bmBitsPixel As Integer
bmBits As Long
End Type
Public Sub SavePictureFromClipBoard(ImagePath As String)
Dim IPic As IPicture
OpenClipboard 0&
OleCreatePictureIndirect getuPicInfo, getIID_IDispatch, True, IPic
SavePicture IPic, ImagePath
CloseClipboard
Set IPic = Nothing
End Sub
Private Function getIID_IDispatch() As GUID
Dim IID_IDispatch As GUID
With IID_IDispatch
.Data1 = &H7BF80980
.Data2 = &HBF32
.Data3 = &H101A:
.Data4(0) = &H8B
.Data4(1) = &HBB
.Data4(2) = &H0
.Data4(3) = &HAA
.Data4(4) = &H0
.Data4(5) = &H30
.Data4(6) = &HC
.Data4(7) = &HAB
End With
getIID_IDispatch = IID_IDispatch
End Function
Private Function getuPicInfo() As uPicDesc
Const PICTYPE_BITMAP = 1
Dim uPicInfo As uPicDesc
' Fill uPicInfo with necessary parts.
With uPicInfo
.Size = Len(uPicInfo) ' Length of structure.
.Type = PICTYPE_BITMAP ' Type of Picture
.hPic = GetClipboardData(xlBitmap) ' Handle to image.
.hPal = xlBitmap ' Handle to palette (if bitmap).
End With
getuPicInfo = uPicInfo
End Function
Public Function getADODBStream(ImagePath As String) As Byte()
Const adTypeBinary = 1
With CreateObject("ADODB.Stream")
.Type = adTypeBinary
.Open
.LoadFromFile (ImagePath)
getADODBStream = .Read()
End With
End Function
Public Function getBase64FromImageFile(ImagePath As String) As String
With CreateObject("MSXml2.DOMDocument")
With .createElement("Base64Data")
.DataType = "bin.base64"
.nodeTypedValue = getADODBStream(ImagePath)
getBase64FromImageFile = .Text
End With
End With
End Function
Public Function getBase64FromByteArray(Bytes() As Byte) As String
With CreateObject("MSXml2.DOMDocument")
With .createElement("Base64Data")
.DataType = "bin.base64"
.nodeTypedValue = Bytes
getBase64FromByteArray = .Text
End With
End With
End Function
Public Function getBytes(Picture1 As IPictureDisp) As Byte()
Dim PicBits() As Byte, PicInfo As Bitmap
GetObject Picture1, Len(PicInfo), PicInfo
ReDim PicBits((PicInfo.bmWidth * PicInfo.bmHeight * 3) - 1) As Byte
GetBitmapBits Picture1, UBound(PicBits), PicBits(0)
getBytes = PicBits()
End Function
Addendum
I am able to read the Byte() from the both the CommandBarButton and the ClipBoard Image. The problem I have i that the Bitmap has a Picture Byte(0 to 767) and a Mask Byte(0 to 767) that combine to form a complete Image. Note: the Mask is sort of background Image that determines the pixel intensity of the Picture. The SavePicture function seems to merge the two parts. The ADODB.Stream saved file returns a Byte(0 to 821).
When copied to the ClipBoard, the Byte() arrays both the ClipBoard IPicture and CommandBarButton Picture are identical.
The three Images above are the CommandBarButton Picture, CommandBarButton Mask, and the Clipboard Image saved to file and then loaded into Image controls.
I am perplexed on how the two Byte() are combined and how the colors are derived from them.
here's my problem.
I am trying to access the printer and change the colour and duplex settings. So far the code I have allows me to change the user preferences of the networked printer. But I have the following two problems below.
1) The codes set's the printer to either simplex or duplex as intended, however is does not set the colour preference correctly!
2) Excel is not automatically picking up the new settings, I still have to go in and manually click the reset button for the new changes to take affect.
Here is the code I am using:
Private Type PRINTER_INFO_9
pDevmode As Long ' Pointer to DEVMODE
End Type
Private Type DEVMODE
dmDeviceName As String * 32
dmSpecVersion As Integer
dmDriverVersion As Integer
dmSize As Integer
dmDriverExtra As Integer
dmFields As Long
dmOrientation As Integer
dmPaperSize As Integer
dmPaperLength As Integer
dmPaperWidth As Integer
dmScale As Integer
dmCopies As Integer
dmDefaultSource As Integer
dmPrintQuality As Integer
dmColor As Integer
dmDuplex As Integer
dmYResolution As Integer
dmTTOption As Integer
dmCollate As Integer
dmFormName As String * 32
dmUnusedPadding As Integer
dmBitsPerPel As Integer
dmPelsWidth As Long
dmPelsHeight As Long
dmDisplayFlags As Long
dmDisplayFrequency As Long
dmICMMethod As Long
dmICMIntent As Long
dmMediaType As Long
dmDitherType As Long
dmReserved1 As Long
dmReserved2 As Long
End Type
Private Declare Function OpenPrinter Lib "winspool.drv" Alias _
"OpenPrinterA" (ByVal pPrinterName As String, phPrinter As Long, _
pDefault As Any) As Long
Private Declare Function GetPrinter Lib "winspool.drv" Alias _
"GetPrinterA" (ByVal hPrinter As Long, ByVal Level As Long, _
buffer As Long, ByVal pbSize As Long, pbSizeNeeded As Long) As Long
Private Declare Function SetPrinter Lib "winspool.drv" Alias _
"SetPrinterA" (ByVal hPrinter As Long, ByVal Level As Long, _
pPrinter As Any, ByVal Command As Long) As Long
Private Declare Function DocumentProperties Lib "winspool.drv" _
Alias "DocumentPropertiesA" (ByVal hwnd As Long, _
ByVal hPrinter As Long, ByVal pDeviceName As String, _
ByVal pDevModeOutput As Long, ByVal pDevModeInput As Long, _
ByVal fMode As Long) As Long
Private Declare Function ClosePrinter Lib "winspool.drv" _
(ByVal hPrinter As Long) As Long
Private Declare Sub CopyMemory Lib "kernel32" Alias "RtlMoveMemory" _
(pDest As Any, pSource As Any, ByVal cbLength As Long)
Private Const DM_IN_BUFFER = 8
Private Const DM_OUT_BUFFER = 2
Private Sub CommandButton1_Click()
Dim sPrinterName As String
Dim my_printer_address As String
Dim hPrinter As Long
Dim Pinfo9 As PRINTER_INFO_9
Dim dm As DEVMODE
Dim yDevModeData() As Byte
Dim nRet As Long
my_printer_address = Application.ActivePrinter
'slice string for printer name (minus port name)
sPrinterName = Left(my_printer_address, InStr(my_printer_address, " on ") - 1)
'Open Printer
nRet = OpenPrinter(sPrinterName, hPrinter, ByVal 0&)
'Get the size of the DEVMODE structure
nRet = DocumentProperties(0, hPrinter, sPrinterName, 0, 0, 0)
If (nRet < 0) Then MsgBox "Cannot get the size of the DEVMODE structure.": Exit Sub
'Get DEVMODE Structure
ReDim yDevModeData(nRet + 100) As Byte
nRet = DocumentProperties(0, hPrinter, sPrinterName, VarPtr(yDevModeData(0)), 0, DM_OUT_BUFFER)
If (nRet < 0) Then
MsgBox "Cannot get the DEVMODE structure."
Exit Sub
End If
'Copy the DEVMODE structure
Call CopyMemory(dm, yDevModeData(0), Len(dm))
'Change DEVMODE Stucture as required
dm.dmColor = 1 ' 1 = colour, 2 = b/w
dm.dmDuplex = 2 ' 1 = simplex, 2 = duplex
'Replace the DEVMODE structure
Call CopyMemory(yDevModeData(0), dm, Len(dm))
'Verify DEVMODE Stucture
nRet = DocumentProperties(0, hPrinter, sPrinterName, VarPtr(yDevModeData(0)), VarPtr(yDevModeData(0)), DM_IN_BUFFER Or DM_OUT_BUFFER)
Pinfo9.pDevmode = VarPtr(yDevModeData(0))
'Set DEVMODE Stucture with any changes made
nRet = SetPrinter(hPrinter, 9, Pinfo9, 0)
If (nRet <= 0) Then MsgBox "Cannot set the DEVMODE structure.": Exit Sub
'Close the Printer
nRet = ClosePrinter(hPrinter)
End Sub
Any help you can provide will be much appreciated!! I have been hitting my head against a wall with this for weeks now!
After some extensive research, I have found the answer I was looking for. I have posted it here, in case anyone has a similar situation.
The main issue I was having was getting excel to accept the new changes with closing the workbook or having to go into the print preferences and click reset.
The solution I came up with was to temporarily set the active printer to another printer then set it back to the printer the settings were changed on, this forces Excel to pick up the new settings.
Here are the Public Types, Functions and Constants:
Public Type PRINTER_INFO_9
pDevmode As Long '''' POINTER TO DEVMODE
End Type
Public Type DEVMODE
dmDeviceName As String * 32
dmSpecVersion As Integer: dmDriverVersion As Integer
dmSize As Integer
dmDriverExtra As Integer
dmFields As Long
dmOrientation As Integer
dmPaperSize As Integer
dmPaperLength As Integer
dmPaperWidth As Integer
dmScale As Integer
dmCopies As Integer
dmDefaultSource As Integer
dmPrintQuality As Integer
dmColor As Integer
dmDuplex As Integer
dmYResolution As Integer
dmTTOption As Integer
dmCollate As Integer
dmFormName As String * 32
dmUnusedPadding As Integer
dmBitsPerPel As Integer
dmPelsWidth As Long
dmPelsHeight As Long
dmDisplayFlags As Long
dmDisplayFrequency As Long
dmICMMethod As Long
dmICMIntent As Long
dmMediaType As Long
dmDitherType As Long
dmReserved1 As Long
dmReserved2 As Long
End Type
Public Declare Function OpenPrinter Lib "winspool.drv" Alias "OpenPrinterA" (ByVal pPrinterName As String, phPrinter As Long, pDefault As Any) As Long
Public Declare Function GetPrinter Lib "winspool.drv" Alias "GetPrinterA" (ByVal hPrinter As Long, ByVal Level As Long, buffer As Long, ByVal pbSize As Long, pbSizeNeeded As Long) As Long
Public Declare Function SetPrinter Lib "winspool.drv" Alias "SetPrinterA" (ByVal hPrinter As Long, ByVal Level As Long, pPrinter As Any, ByVal Command As Long) As Long
Public Declare Function DocumentProperties Lib "winspool.drv" Alias "DocumentPropertiesA" (ByVal hWnd As Long, ByVal hPrinter As Long, ByVal pDeviceName As String, _
ByVal pDevModeOutput As Long, ByVal pDevModeInput As Long, _
ByVal fMode As Long) As Long
Public Declare Function ClosePrinter Lib "winspool.drv" (ByVal hPrinter As Long) As Long
Public Declare Sub CopyMemory Lib "kernel32" Alias "RtlMoveMemory" (pDest As Any, pSource As Any, ByVal cbLength As Long)
Public Const DM_IN_BUFFER = 8
Public Const DM_OUT_BUFFER = 2
This is the routine i am using to set the new values:
Public Sub SetPrinterProperty(ByVal sPrinterName As String, ByVal iPropertyType As Long)
Dim PrinterName, sPrinter, sDefaultPrinter As String
Dim Pinfo9 As PRINTER_INFO_9
Dim hPrinter, nRet As Long
Dim yDevModeData() As Byte
Dim dm As DEVMODE
'''' STROE THE CURRENT DEFAULT PRINTER
sDefaultPrinter = sPrinterName
'''' USE THE FULL PRINTER ADDRESS TO GET THE ADDRESS AND NAME MINUS THE PORT NAME
PrinterName = Left(sDefaultPrinter, InStr(sDefaultPrinter, " on ") - 1)
'''' OPEN THE PRINTER
nRet = OpenPrinter(PrinterName, hPrinter, ByVal 0&)
'''' GET THE SIZE OF THE CURRENT DEVMODE STRUCTURE
nRet = DocumentProperties(0, hPrinter, PrinterName, 0, 0, 0)
If (nRet < 0) Then MsgBox "Cannot get the size of the DEVMODE structure.": Exit Sub
'''' GET THE CURRENT DEVMODE STRUCTURE
ReDim yDevModeData(nRet + 100) As Byte
nRet = DocumentProperties(0, hPrinter, PrinterName, VarPtr(yDevModeData(0)), 0, DM_OUT_BUFFER)
If (nRet < 0) Then MsgBox "Cannot get the DEVMODE structure.": Exit Sub
'''' COPY THE CURRENT DEVMODE STRUCTURE
Call CopyMemory(dm, yDevModeData(0), Len(dm))
'''' CHANGE THE DEVMODE STRUCTURE TO REQUIRED
dm.dmDuplex = iPropertyType ' 1 = simplex, 2 = duplex
'''' REPLACE THE CURRENT DEVMODE STRUCTURE WITH THE NEWLEY EDITED
Call CopyMemory(yDevModeData(0), dm, Len(dm))
'''' VERIFY THE NEW DEVMODE STRUCTURE
nRet = DocumentProperties(0, hPrinter, PrinterName, VarPtr(yDevModeData(0)), VarPtr(yDevModeData(0)), DM_IN_BUFFER Or DM_OUT_BUFFER)
Pinfo9.pDevmode = VarPtr(yDevModeData(0))
'''' SET THE DEMODE STRUCTURE WITH ANY CHANGES MADE
nRet = SetPrinter(hPrinter, 9, Pinfo9, 0)
If (nRet <= 0) Then MsgBox "Cannot set the DEVMODE structure.": Exit Sub
'''' CLOSE THE PRINTER
nRet = ClosePrinter(hPrinter)
'''' GET THE FULL PRINTER NAME FOR THE CUTE PDF WRITER
sPrinter = GetPrinterFullName("CutePDF")
'''' CHECK TO MAKE SURE THE CUTEPDF WAS FOUND
If sPrinter <> vbNullString Then
'''' THIS FORCES EXCEL TO ACCEPT THE NEW CHANGES THAT HAVE BEEN MADE TO THE PRINTER SETTINGS
'''' SET THE ACTIVE PRINTER TEMPERARILLY TO THE CUTE PDF WRITER
Application.ActivePrinter = sPrinter
'''' SET THE PRINTER BACK TO THE DEFAULY FOLLOW ME.
Application.ActivePrinter = sDefaultPrinter
End If
End Sub
I then call either of these two subs to set set preferences:
Public Sub SetDuplex(ByVal sPrinterName As String, iDuplex As Long)
SetPrinterProperty sPrinterName, iDuplex
End Sub
Public Sub SetSimplex(ByVal sPrinterName As String, iDuplex As Long)
SetPrinterProperty sPrinterName, iDuplex
End Sub
Awesome. Thank you for this fix. Our office recently switched to Windows 10 and Office 16 and my old duplex code no longer worked for printing out worksheets in duplex mode. Your code is incredibly complicated, but it works (for reasons beyond my understanding as a novice programmer) and saves a lot of paper from being wasted. Thank you very much. I did notice one thing about your function that needs to be addressed. There is a call to another function you did not provide.
sPrinter = GetPrinterFullName("CutePDF")
Coincidentally I happened to have the function GetPrinterFullName() in another module so it was running but not returning the full name of "CutePDF". That was because "CutePDF" does not exist on my computer. So I simply went to settings, set the default to "Microsoft Print to PDF" and then did a small test routine (below) to get the full name of the active default printer:
sub getActivePrinterFullAddress()
debug.print application.activeprinter
end sub
This returned "Microsoft Print to PDF on Ne03:" So any user could send the full name of any second printer to your function by adding a 3rd variable and avoid the call to GetPrinterFullName(), or they can hard code the name into your function like I did to avoid the call. Or they can add the following function to the module: (I've been to 30 different sites this morning to find a solution, and yours is the one that works. But the credits for the following function are inside the function below. It is not my code. I think it is credited to Frans Bus)
Public Function GetPrinterFullName(Printer As String) As String
' This function returns the full name of the first printerdevice that
matches Printer.
' Full name is like "PDFCreator on Ne01:" for a English Windows and like
' "PDFCreator sur Ne01:" for French.
' Created: Frans Bus, 2015. See http://pixcels.nl/set-activeprinter-excel
' see http://blogs.msdn.com/b/alejacma/archive/2008/04/11/how-to-read-a-
registry-key-and-its-values.aspx
' see http://www.experts-exchange.com/Software/Microsoft_Applications/Q_27566782.html
Const HKEY_CURRENT_USER = &H80000001
Dim regobj As Object
Dim aTypes As Variant
Dim aDevices As Variant
Dim vDevice As Variant
Dim sValue As String
Dim v As Variant
Dim sLocaleOn As String
' get locale "on" from current activeprinter
v = Split(Application.ActivePrinter, Space(1))
sLocaleOn = Space(1) & CStr(v(UBound(v) - 1)) & Space(1)
' connect to WMI registry provider on current machine with current user
Set regobj = GetObject("WINMGMTS:{impersonationLevel=impersonate}!\\.\root\default:StdRegProv")
' get the Devices from the registry
regobj.EnumValues HKEY_CURRENT_USER, "Software\Microsoft\Windows NT\CurrentVersion\Devices", aDevices, aTypes
' find Printer and create full name
For Each vDevice In aDevices
' get port of device
regobj.GetStringValue HKEY_CURRENT_USER, "Software\Microsoft\Windows NT\CurrentVersion\Devices", vDevice, sValue
' select device
If Left(vDevice, Len(Printer)) = Printer Then ' match!
' create localized printername
GetPrinterFullName = vDevice & sLocaleOn & Split(sValue, ",")(1)
Exit Function
End If
Next
' at this point no match found
GetPrinterFullName = vbNullString
End Function
I'm currently in the process of upscaling an Excel solution to a web solution. In this process, I need to upload the existing data into the new (SQL Server) database.
Problem is, that I also need to upload the images that are stored in the Excel file (as shapes). In the database, they will be stored as bytearray in PNG format.
What is the best way to retrieve the source of any embedded image?
I'm currently thinking of either using ws.Shapes("img_1").CopyPicture and some API functions to retrieve it - but so far, got stuck in figuring out the proper API functions. Also, not sure if there isn't an easier/more elegant way...
If you don't mind getting all images as files in your disk and afterwards uploading those to your database, you could just save the Excel workbook or worksheet as "Web Page".
That will create a html file and a directory filled with whatever images (one PNG file per image) the original Excel file has.
Okay, finally found a solution. Not sure this is the most elegant version - and right now it requires IrfanView or another converter - but it does the job. Can be called with fctStrConvertImageToString(Sheets("YourSheet").Shapes("YorImage")) and will return the PBG of this image as string:
Option Explicit
Private Type GUID
Data1 As Long
Data2 As Integer
Data3 As Integer
Data4(8) As Byte
End Type
Private Type PICTDESC
cbSize As Long
picType As Long
hImage As Long
End Type
Private Declare Function OpenClipboard& Lib "user32" (ByVal hwnd&)
Private Declare Function EmptyClipboard& Lib "user32" ()
Private Declare Function GetClipboardData& Lib "user32" (ByVal wFormat%)
Private Declare Function SetClipboardData& Lib "user32" (ByVal wFormat&, ByVal hMem&)
Private Declare Function CloseClipboard& Lib "user32" ()
Private Declare Function CopyImage& Lib "user32" (ByVal handle&, ByVal un1&, ByVal n1&, ByVal n2&, ByVal un2&)
Private Declare Function IIDFromString Lib "ole32" (ByVal lpsz As String, ByRef lpiid As GUID) As Long
Private Declare Function OleCreatePictureIndirect Lib "olepro32" (pPictDesc As PICTDESC, ByRef riid As GUID, ByVal fOwn As Long, ByRef ppvObj As IPicture) As Long
Public Function fctStrConvertImageToString(shp As Shape) As String
Const cStrPath As String = "C:\Temp\"
Const cStrFileName As String = "temp"
Const cStrSourceExtension As String = "bmp"
Const cStrTargetExtension As String = "png"
Dim strSource As String, strTarget As String
If shp.Type <> msoPicture Then Exit Function
shp.CopyPicture 1, xlBitmap
strSource = cStrPath & cStrFileName & "." & cStrSourceExtension
strTarget = cStrPath & cStrFileName & "." & cStrTargetExtension
subSavePicAsBitmap strSource
subConvertFile strSource, strTarget
fctStrConvertImageToString = fctStrReadFile(strTarget)
Kill strSource
Kill strTarget
End Function
Private Sub subSavePicAsBitmap(strFile As String)
Const cStrPictureIID = "{7BF80981-BF32-101A-8BBB-00AA00300CAB}"
Dim hCopy&: OpenClipboard 0&
Dim iPic As IPicture
Dim tIID As GUID
Dim tPICTDEST As PICTDESC
Dim lngReturn As Long
hCopy = CopyImage(GetClipboardData(2), 0, 0, 0, &H4)
CloseClipboard
If hCopy = 0 Then Exit Sub
lngReturn = IIDFromString(StrConv(cStrPictureIID, vbUnicode), tIID)
If lngReturn Then Exit Sub
With tPICTDEST
.cbSize = Len(tPICTDEST)
.picType = 1
.hImage = hCopy
End With
lngReturn = OleCreatePictureIndirect(tPICTDEST, tIID, 1, iPic)
SavePicture iPic, strFile
End Sub
Private Sub subConvertFile(strSource As String, strTarget As String)
Const cStrConverter = """c:\Program Files (x86)\IrfanView\i_view32.exe"""
Shell cStrConverter & " " & strSource & " /convert=" & strTarget, 0
End Sub
Private Function fctStrReadFile(strFile As String)
Dim hFile As Long
hFile = FreeFile
Open strFile For Binary Access Read As #hFile
fctStrReadFile = Input$(LOF(hFile), hFile)
Close #hFile
End Function
I am new to Active Directory.
I have a VBA Excel Add-In that should run if, and only if, the computer that it is running on is currently logged into the Active Directory, whether locally or through a VPN.
Knowing the domain name, how would I retrieve the user name for the currently logged in user?
Thanks!
I know it's kinda late, but I went through hell last year to find the following code, that can return the username ("fGetUserName()") or the full name ("DragUserName()"). You don't even need to know the ad / dc address..
Hope this is helpful to anyone who consults this question.
Private Type USER_INFO_2
usri2_name As Long
usri2_password As Long ' Null, only settable
usri2_password_age As Long
usri2_priv As Long
usri2_home_dir As Long
usri2_comment As Long
usri2_flags As Long
usri2_script_path As Long
usri2_auth_flags As Long
usri2_full_name As Long
usri2_usr_comment As Long
usri2_parms As Long
usri2_workstations As Long
usri2_last_logon As Long
usri2_last_logoff As Long
usri2_acct_expires As Long
usri2_max_storage As Long
usri2_units_per_week As Long
usri2_logon_hours As Long
usri2_bad_pw_count As Long
usri2_num_logons As Long
usri2_logon_server As Long
usri2_country_code As Long
usri2_code_page As Long
End Type
Private Declare Function apiNetGetDCName Lib "Netapi32.dll" Alias "NetGetDCName" (ByVal servername As Long, ByVal DomainName As Long, bufptr As Long) As Long
Private Declare Function apiNetAPIBufferFree Lib "Netapi32.dll" Alias "NetApiBufferFree" (ByVal buffer As Long) As Long
Private Declare Function apilstrlenW Lib "kernel32" Alias "lstrlenW" (ByVal lpString As Long) As Long
Private Declare Function apiNetUserGetInfo Lib "Netapi32.dll" Alias "NetUserGetInfo" (servername As Any, UserName As Any, ByVal level As Long, bufptr As Long) As Long
Private Declare Sub sapiCopyMem Lib "kernel32" Alias "RtlMoveMemory" (Destination As Any, Source As Any, ByVal Length As Long)
Private Declare Function apiGetUserName Lib "advapi32.dll" Alias "GetUserNameA" (ByVal lpBuffer As String, nSize As Long) As Long
Private Declare Function GetUserName Lib "advapi32.dll" Alias "GetUserNameA" (ByVal lpBuffer As String, nSize As Long) As Long
Private Declare Function GetComputerName Lib "kernel32.dll" Alias "GetComputerNameA" (ByVal lpBuffer As String, nSize As Long) As Long
Private strUserID As String
Private strUserName As String
Private strComputerName As String
Private Const MAXCOMMENTSZ = 256
Private Const NERR_SUCCESS = 0
Private Const ERROR_MORE_DATA = 234&
Private Const MAX_CHUNK = 25
Private Const ERROR_SUCCESS = 0&
Public Function fGetUserName() As String
' Returns the network login name
Dim lngLen As Long, lngRet As Long
Dim strUserName As String
strUserName = String$(254, 0)
lngLen = 255
lngRet = apiGetUserName(strUserName, lngLen)
If lngRet Then
fGetUserName = Left$(strUserName, lngLen - 1)
End If
End Function
Private Sub Class_Initialize()
On Error Resume Next
'Returns the network login name
Dim strTempUserID As String, strTempComputerName As String
'Create a buffer
strTempUserID = String(100, Chr$(0))
strTempComputerName = String(100, Chr$(0))
'Get user name
GetUserName strTempUserID, 100
'Get computer name
GetComputerName strTempComputerName, 100
'Strip the rest of the buffer
strTempUserID = Left$(strTempUserID, InStr(strTempUserID, Chr$(0)) - 1)
Let strUserID = LCase(strTempUserID)
strTempComputerName = Left$(strTempComputerName, InStr(strTempComputerName, Chr$(0)) - 1)
Let strComputerName = LCase(strTempComputerName)
Let strUserName = DragUserName(strUserID)
End Sub
Public Property Get UserID() As String
UserID = strUserID
End Property
Public Property Get UserName() As String
UserName = strUserName
End Property
Public Function DragUserName(Optional strUserName As String) As String
On Error GoTo ErrHandler
Dim pBuf As Long
Dim dwRec As Long
Dim pTmp As USER_INFO_2
Dim abytPDCName() As Byte
Dim abytUserName() As Byte
Dim lngRet As Long
Dim i As Long
' Unicode
abytPDCName = fGetDCName() & vbNullChar
If strUserName = "" Then strUserName = fGetUserName()
abytUserName = strUserName & vbNullChar
' Level 2
lngRet = apiNetUserGetInfo( _
abytPDCName(0), _
abytUserName(0), _
2, _
pBuf)
If (lngRet = ERROR_SUCCESS) Then
Call sapiCopyMem(pTmp, ByVal pBuf, Len(pTmp))
DragUserName = fStrFromPtrW(pTmp.usri2_full_name)
End If
Call apiNetAPIBufferFree(pBuf)
ExitHere:
Exit Function
ErrHandler:
DragUserName = vbNullString
Resume ExitHere
End Function
Public Property Get ComputerName() As String
ComputerName = strComputerName
End Property
Private Sub Class_Terminate()
strUserName = ""
strComputerName = ""
End Sub
Public Function fGetDCName() As String
Dim pTmp As Long
Dim lngRet As Long
Dim abytBuf() As Byte
lngRet = apiNetGetDCName(0, 0, pTmp)
If lngRet = NERR_SUCCESS Then
fGetDCName = fStrFromPtrW(pTmp)
End If
Call apiNetAPIBufferFree(pTmp)
End Function
Public Function fStrFromPtrW(pBuf As Long) As String
Dim lngLen As Long
Dim abytBuf() As Byte
' Get the length of the string at the memory location
lngLen = apilstrlenW(pBuf) * 2
' if it's not a ZLS
If lngLen Then
ReDim abytBuf(lngLen)
' then copy the memory contents
' into a temp buffer
Call sapiCopyMem( _
abytBuf(0), _
ByVal pBuf, _
lngLen)
' return the buffer
fStrFromPtrW = abytBuf
End If
End Function
EDITED: If I understand your situation properly, then you might be going about this the wrong way.
When your app starts up, you could do a simple ping against a machine that the user would only be able to see if they were connected to your network, whether they log into the local network or if they are connected via the VPN.
If they already have access to your local network, it means they've already authenticated against whatever machanism, whether it's Active Directory or something else, and it means they are "currently logged in".
On a side note, Active Directory by itself doesn't know if someone is logged in. There's no way you can do something like:
ActiveDirectory.getIsThisUserLoggedIn("username");
Active Directory only acts as a mechanism for user metadata, security, and authentication.
Try this
MsgBox Environ("USERNAME")
This function returns full name of logged user:
Function UserNameOffice() As String
UserNameOffice = Application.UserName
End Function