While I'm connecting the SIM5360E module with USB to uart converter and am sending at+commands through putty, I am getting some null values as shown below.
Please help me to rectify the issue:
AT+CGPS=1,1
AT+CGPSINFO
result
+CGPSINFO:,,,,,,,,
OK
I am trying with below code
And i suppose to get the location details in between the commas as shown in result
am getting only commas as result
AT+CGPS=1,1
AT+CGPSINFO
result
CGPS,,,,,,
Related
I am following this github example for understanding OFDM on gnuradio-companion, I am able to execute ofdm_tx individually (64 and 512 FFT point) without any issues, but when I connect these two in single graph, I am able to get spectrum from ofdm_tx (no output from ofdm_rx or getting straight line).
My question here, each time I close my output spectrum, my tool get hanged and in background (inside gnu-companion) I observe the following message tarin (attached, printscreen). Similar thing also observed when I run ofdm_rx individually.
Error message in Console :
packet_headerparser_b :info: Detected an invalid packet at item 1448.
header_payload_demux :info :parser returned #f
Please guide me in this regard,
by selecting "NO" for vector source "Repeat" variable , issue sorted out (no hang), but not able to see spectrum anymore.
I'm using a Telit UL865-NAD to connect to a webpage to get data from a php file.
The main problem is that the HTTPRCV command hangs.
See code below:
OK
AT#CIMI
#CIMI: 730011235559846
OK
AT+CCID
+CCID: 89560100000992123469
OK
AT+CGMI
Telit
OK
AT+CGMM
UL865-NAD
OK
AT+CGMR
12.00.716
OK
AT+CGDCONT=1,"IP","imovil.entelpcs.cl"
AT+CGDCONT=1,"IP","imovil.entelpcs.cl"
OK
AT#SGACT=1,1
#SGACT: 10.166.148.143
OK
AT#HTTPCFG=0,"www.xxxx-xxxxxx.com",80,0,,,0,120,1
AT#HTTPCFG=0,"www.xxxx-xxxxxx.com",80,0,,,0,120,1
OK
AT#HTTPQRY=0,0,"/Inagrap/"
OK
#HTTPRING: 0,200,"text/html;charset=ISO-8859-1",1136
AT#HTTPRCV=0
The AT#HTTPQRY command, refers to the directory where the php file resides.
A second issue,
If I include the php file:
AT#HTTPQRY=0,0,"/Inagrap/my.php?D1=val1&D2=val2..."
The HTTPRING indicates '0' data
*** Edit Further info
If I test the page through a browser it gives me a response, yet
testing through the modem, HTTPRING indicates '0' data.
The page inserts the data passed in with the GET, to a database.
If I access the page through a browser, data gets inserted into the database.
But run through the modem, nothing happens.
It's strange the modem gives me responses indicating that I connect to the page, it indicates a http status of 200, yet no data is returned and the web code is not executed.
Why?
After the AT#SGACT command, an AT&K0 command is required to turn off flow control.
Two days wracking my brain for this simple omission.
I'm trying to get a BG95 to activate on hologram.
Here are my commands:
AT+QCFG="band",F,180A,180A OK
AT+QCFG="iotopmode",2 OK
AT+QCFG="nwscanseq",020301 OK
AT+QCFG="nwscanmode",0 OK
AT+QCFG="snrscan",0 OK
AT+QICSGP=1,1,"hologram","","",1 OK
AT+QIACT=1 ERROR
At first I thought it was antenna/signal related so I ran AT+CSQ and got this:
+csq: 11,99
This tells me I have a good signal I believe.
Next I tried AT+QNWINFO and get this:
+QNWINFO: "eMTC","311480","LTE BAND 13",5230
In my mind this is saying it's connected to a network.
After trying that I tried to activate again and got this:
AT+QIACT=1
ERROR
The weird thing is it activated just fine about a week ago with pure AT commands. I did try and use an Arduino library with it (WisLTEBG96TCPIP) which may have changed a setting in it. I've done a factory reset but the it still woln't activate.
Another strange thing is the hologram dashboard. Every once and a while it will show the SIM as connected, even though I can't activate.
I have tried with 2 different SIM cards any get the same activation error.
Any help would be greatly appreciated!
Verizon has cut off all non ODI products. If your hardware has not been Verizon ODI 'certified' it will no longer be allow to be connected to their network, I have 5 new pet rocks thanks to them. The solution is to purchase new modems from vendors that have been through the Verizon ODI program or switch carriers.
I had the same problem before, after a lot of maling with network operator I find out that there isn't a LTE-CAT-M1 (eMTC) network in my area, I tested in another area successfully
Also before setting AT+QCFG commands try AT+CFUN = 0
and after setting AT+QCFG commands try AT+CFUN = 1 .
before sending AT+QIACT, try 'AT+CEREG?' command several times and tell me what is the return of it
http://pastebin.com/86JXkUBf
This is my Arduino code that I am using as a status indicator for me and my roommate. The code as working completely fine until I decided to be able to edit the first line on the display, which is the sainsmart LCD keypad shield. Now, when I verify the code in the arduino IDE, i get the following set of errors:
sketch_jul22b.cpp:15:81: error: expected unqualified-id before '\x593a'
sketch_jul22b.cpp:15:81: error: expected ‘}’ before '\x593a'
sketch_jul22b.cpp:15:81: error: expected ‘,’ or ‘;’ before '\x593a'
sketch_jul22b.cpp:15:88: error: expected declaration before ‘}’ token
I would appreciate it very much if somebody would tell me:
1) what these errors mean.
2) How to resolve them.
Thanks!
corrected code that compiles.
http://pastebin.com/j5B37UUP
#praks411 was correct, but there were some typo's and need to use lcd.print instead of lcd.write.
I'm not sure exactly which line you have edited but looking at your code it seems to me that the status String must be in double quotes. Also there should be , instead of . after "Awesomeness"
So instead of
String top[] = {'Status:', 'Adam:', 'Oliver:', 'Adam & Oliver:', 'Awesomeness'. 'OBEY:'};
You should have
String top[] = {"Status:", "Adam:", "Oliver:", "Adam & Oliver:", "Awesomeness", "OBEY:"};
I'm having an issue with Quickfixn and I'm hoping someone with more experience working with it can shed some light on an issue I'm facing. For some reason, messages are getting rejected by the QuickFix engine because of repeating tags... I expect to have repeating tags and so I set the UseDataDictionary flag = Y in my config file but messages are still getting rejected. Has anyone experienced a similar issue ?
The message I'm receiving looks like :
8=FIXT.1.1 9=421 35=AE 34=8 1128=8 49=XXX 56=YYY 52=20130501-15:45:53 552=1 54=2 37=130501-5 11=NOREF 826=0 78=1 79=default 80=1000000.00 5967=12167800.00 453=4 448=ITXT 452=3 447=D 448=TEST 452=1 447=D 448=LMEB 452=16 447=D 448=FRTB 452=11 447=D 571=6718487 150=F 32=1000000.00 15=USD 1056=12167800.00 31=12.1678 194=12.1678 195=0 64=20130503 63=0 60=20130501-00:00:00 75=20130501 1057=Y 460=4 167=FOR 65=SP 55=USD/MXN 10=203
8=FIXT.1.1 9=124 35=3 34=8 49=XXX 52=20130501-15:45:54.209 56=YYY 45=8 58=Tag appears more than once 371=448 372=AE 373=13 10=210
my config file looks like this:
[DEFAULT]
ConnectionType=initiator
HeartBtInt=30
ReconnectInterval=10
SocketReuseAddress=Y
FileStorePath=D:\Store
FileLogPath=D:\Log
[SESSION]
BeginString=FIXT.1.1
SenderCompID=XXX
TargetCompID=YYY
DefaultApplVerId = FIX.5.0SP1
UseDataDictionary=Y
AppDataDictionary=D:\Interface\FIX50SP1.xml
StartDay=sunday
StartTime=20:55:00
EndTime=06:05:00
EndDay=saturday
SocketConnectHost=1.1.1.1
SocketConnectPort=8443
Any help would be greatly appreciated! Thank you.
Often this happens because there is a field in a repeating group that is not specified in the DataDictionary. The parser sees the field and assumes the repeating group has ended. It continues parsing fields as if they are not part of a group. If it sees a duplicate field in this context, the parser will report an error.
You may clone and modify FIX Data Dictionary (D:\Interface\FIX50SP1.xml) to fit your needs, if you need to process "invalid" messages. Or you may disable message validation.