sometimes my selenium tests get timeouts these suggestions: How do you get selenium to recognize that a page loaded? did not fix my problem. It mostly happens at the beginning of the test when i use open or openAndWait. The odd thing is the page actually gets opend but the test just stops and does not execute fruther. I use the beta-2 version and multiwindow true. I call my browsers with the custom command. I'm open for any suggestions.
thx
kuku
Have you tried putting a fixed pause (several seconds) after openAndWait? From my experience all "opens" and "clicks" in selenium (even *AndWait ones) do not guarantee you that the page is fully loaded in the browser before the next selenium command is processed. That's why I always add a small pause after such commands.
Even if you see the page being rendered in the browser, this doesn't necessarily mean everything is available to the Selenium's command processor at that moment.
This works for me in IE6, IE7, IE8, FF, Chrome:
<tr>
<td>waitForCondition</td>
<td>
(selenium.browserbot.getCurrentWindow().$$("body").length == 1) ? true : false;
</td>
<td>10000</td>
</tr>
It just polls the target window and checks for the body element. It is still susceptible to a timeout, however, but you can set that to whatever you like.
Note: the above code uses Prototype JS to get the body element. This is not required but will need some modifications if you are using another JS lib.
I had a similar problem, mine will just timeout no matter what.
I see the page is rendered completely but for some reason selenium.open(relative_url) will just timeout.
I tried setting timeout to like 120 seconds and still the same issue. Setting the speed to really slow didn't help either.
I fixed it by handling the exception with a try/catch and basically proceed with validation if the page really rendered or not (works like a charm) so my code looks like this:
try {
selenium.open(relative_url);
} catch (Exception e) {
// check if page rendered completely here
}
// continue
Related
Everytime I try to access this website and open google-chrome-devtools I am unable to inspect any of the elements through the Inspector as the UI is having an overlay along with a message Paused in debugger.
The upvoted and accepted answer of this discussion says to check the Source tab, check under the Event Listener Breakpoints panel if you've set any breakpoints under 'Mouse'. I have cross checked that none of the Sources -> EventListenerBreakpoint are set.
The upvoted and accepted answer of this discussion says to check if the little octagonal stop/pause sign (at lower left of Chrome "Sources") is colored (blue or purple). I am not sure why do I need to do that additionally for selected websites.
Snapshot:
The upvoted and accepted answer of this discussion speaks about the Manual Steps.
All the solutions seem to point towards the manual process. But this issue seems to me the root cause behind Selenium being unable to getPageSource().
Code trials:
System.setProperty("webdriver.chrome.driver", "C:\\Utility\\BrowserDrivers\\chromedriver.exe");
ChromeOptions options = new ChromeOptions();
options.addArguments("start-maximized");
options.addArguments("disable-infobars");
options.addArguments("--disable-extensions");
WebDriver driver = new ChromeDriver(options);
driver.get("http://rd.huangpuqu.sh.cn/website/html/shprd/shprd_tpxw/List/list_0.htm");
Output: Chrome opens but doesn't navigates to the url.
So my questions are:
In which case can Paused in debugger error occurs?
Is it an error from the frontend development?
How can I bypass this error during the Automated Tests through Selenium?
In which cases can the Paused in debugger error occur?
Anytime you are accessing this page with the dev tools open. The debugger; line will pause javascript execution, but browsers will ignore it if the dev tools are closed.
Is it an error from the frontend development?
In this case, no--they're deliberately trying to keep you out. The purpose of this function is to pause execution and then redirect your browser to a different page if it takes longer than 100ms to resume. I would speculate that this is designed to interfere with automated crawlers like selenium, because a regular user wouldn't be affected and a human developer can just hack around it.
How can I bypass this error during the Automated Tests through Selenium?
My first recommendation would be to try running Selenium headlessly, if that's an option. If not, use the hotkey to resume execution (F8). You can use whatever method you like for generating a keypress; with the java.awt package it will look something like this:
Robot robot = null;
try
{
robot = new Robot();
}
catch(Exception e)
{
//handle failure
}
robot.keyPress(KeyEvent.VK_F8);
Remember that you have to trigger this within 100ms, so use whatever logic you like to detect the block and respond quickly. If you just want something quick and dirty, I would just make it spam F8 keypresses every 50ms for a period of time until you're certain the page has loaded.
EDIT: On further investigation, this page is extremely messy and hostile to anyone with the dev tools open. There is not one but several functions that trigger debugger;and they get called repeatedly on a timer for as long as you're on the page. Running headlessly seems like the best choice, unless you want to continue spamming F8 for the entire session.
Everytime I try to access this website and open google-chrome-devtools I am unable to inspect any of the elements through the Inspector as the UI is having an overlay along with a message Paused in debugger.
The upvoted and accepted answer of this discussion says to check the Source tab, check under the Event Listener Breakpoints panel if you've set any breakpoints under 'Mouse'. I have cross checked that none of the Sources -> EventListenerBreakpoint are set.
The upvoted and accepted answer of this discussion says to check if the little octagonal stop/pause sign (at lower left of Chrome "Sources") is colored (blue or purple). I am not sure why do I need to do that additionally for selected websites.
Snapshot:
The upvoted and accepted answer of this discussion speaks about the Manual Steps.
All the solutions seem to point towards the manual process. But this issue seems to me the root cause behind Selenium being unable to getPageSource().
Code trials:
System.setProperty("webdriver.chrome.driver", "C:\\Utility\\BrowserDrivers\\chromedriver.exe");
ChromeOptions options = new ChromeOptions();
options.addArguments("start-maximized");
options.addArguments("disable-infobars");
options.addArguments("--disable-extensions");
WebDriver driver = new ChromeDriver(options);
driver.get("http://rd.huangpuqu.sh.cn/website/html/shprd/shprd_tpxw/List/list_0.htm");
Output: Chrome opens but doesn't navigates to the url.
So my questions are:
In which case can Paused in debugger error occurs?
Is it an error from the frontend development?
How can I bypass this error during the Automated Tests through Selenium?
In which cases can the Paused in debugger error occur?
Anytime you are accessing this page with the dev tools open. The debugger; line will pause javascript execution, but browsers will ignore it if the dev tools are closed.
Is it an error from the frontend development?
In this case, no--they're deliberately trying to keep you out. The purpose of this function is to pause execution and then redirect your browser to a different page if it takes longer than 100ms to resume. I would speculate that this is designed to interfere with automated crawlers like selenium, because a regular user wouldn't be affected and a human developer can just hack around it.
How can I bypass this error during the Automated Tests through Selenium?
My first recommendation would be to try running Selenium headlessly, if that's an option. If not, use the hotkey to resume execution (F8). You can use whatever method you like for generating a keypress; with the java.awt package it will look something like this:
Robot robot = null;
try
{
robot = new Robot();
}
catch(Exception e)
{
//handle failure
}
robot.keyPress(KeyEvent.VK_F8);
Remember that you have to trigger this within 100ms, so use whatever logic you like to detect the block and respond quickly. If you just want something quick and dirty, I would just make it spam F8 keypresses every 50ms for a period of time until you're certain the page has loaded.
EDIT: On further investigation, this page is extremely messy and hostile to anyone with the dev tools open. There is not one but several functions that trigger debugger;and they get called repeatedly on a timer for as long as you're on the page. Running headlessly seems like the best choice, unless you want to continue spamming F8 for the entire session.
I am creating a suite of tests (using Geb/Spock) for a web site. In one of them, the element I want to access is on the top of the page, so, to make sure that is visible, I want to scroll to the top of the page.
The command I am using is:
browser.js.exec('window.scrollTo(0, 0);')
or variations of it like
js.exec('window.scrollTo(0, 0);')
or other alternative like:
js.exec('window.scrollBy(0, -250);')
None of them makes the page scroll up, and when executing I get the following error (it is the only error, no other feedback). The error message using the other options listed above is identical (other than the command itself):
Condition not satisfied:
browser.js.exec('window.scrollTo(0, 0);')
| | |
| | null
| geb.js.JavascriptInterface#4019094f
geb.Browser#3dcac33e
at UserCreatesCompany.Go to Home Page and click on the log to
GitHub button as user User1(UserCreatesCompany.groovy:170)
I can not interpret the message that 'exec' is null. What exactly it means?
To make things more interesting, at the end of this script I am running the following cleanup procedure
js.exec('window.scrollTo(0, document.body.scrollHeight);')
DeleteButton.click()
$("button",'data-automation-id':"button-modal-yes").click()
}
and that works well: the page scrolls down. So, does not seem a problem about some missing library.
Any suggestion of what I may be doing wrong?
The version of the different components I am using is:
groovyVersion = '2.5.4'
gebVersion = '2.3'
seleniumVersion = '3.141.59'
chromeDriverVersion = '2.45'
First of all, you should not need to ever manually scroll the page to make elements visible - Selenium WebDriver which is underpinning Geb will do that for you automatically as soon as you start interacting (clicking, setting value, etc) with content.
Secondly, the failure you are getting is a failed assertion coming from a statement in an automatically asserted (then: or expect:) Spock block. It feels to me that you don't understand a concept which is core to Spock and therefore you should read about it in the manual first. It should make the failure you're getting clearer.
Thanks for the answer. Clearly: I was not fully aware of the different constrains the different blocks impose on what is executable or not. The manual is pretty clear once you have stumbled!
I am intrigued by your first assertion pointing that Selenium WebDriver will move to the element as soon as I interact with it. That was my understanding but it was not working. I made sure the element in question had a unique identifier, but still, it was not able to found it if the element had to be found by scrolling up. On the other hand it worked smoothly when locating the element WebDriver scrolled the page down.
Thanks again for the explanation. I have learn something new today!
My app displays an error dialog whenever a JavaScript error occurs. This is always a bad sign, so I want to set up my tests so that, if the error dialog appears, it causes the test to fail there and then.
So I'd like to do something like (very much pseudocode!);
// start a new 'guard' thread;
start {
found = this.driver.wait(untilVisible(By.css('.myErrorDialog')), VERY_LONG_TIMEOUT);
if (found) {
// the error dialog appeared! That's bad!
throw();
}
}
// now run the test
login();
clickButton();
testBannerContains();
But I'm having trouble and I think it has to do with the way Selenium schedules actions.
What I've found is that for a single driver, I can only schedule one thing at a time, so the guard I set up early in the test blocks the body of the test from starting.
Is there a better way to handle conditions like 'this should never happen', or a way to create two independent threads in the same test?
So the problem with the code you have is that it immediately runs it and waits for a VERY_LONG_TIMEOUT amount of time for that error dialog to appear. Since it never does, it continues to wait. You have already discovered that is not what you want... ;)
I haven't done anything like this but I think you want a JS event handler that watches for the event that is triggered when the error dialog appears. See the link below for some guidance there.
Can my WebDriver script catch a event from the webpage?
One option would be to watch for that event to fire and then store true (or whatever) in some JS variable. Before leaving a page, check to see if the variable is set to true and if so, fail the test. You can set and get JS variables using JavascriptExecutor. Some google searches should get you all you need to use it.
Every now and then my selenium tests randomly fail with an "element X not found" error message. I do a simple select by ID, eg.
click('sideBar_queryButton')
When I use the dom inspector, the element is there, so I wonder why selenium doesn't find it sometimes. When I run the same test again, it works or it breaks again, there seems to be no reliable way of reproducing it. Even tests which are there for ages seem to randomly break and then magically work again. Inserting a few sleep statements sometimes helps but not reliably. So I wonder if I'm using it incorrectly. Has anyone else had these problems with selenium and if so, how did you fix them?
Edit: I found it to be much more reliable to put some test markers in my pages and wait for them to appear. If you use asynchronous operations which might create race conditions in your tests, inserting a test marker into your html after you finish the operation worked pretty well for me. E.g.
$('<div>').addClass("testMarker").append("OpXYZFinished").appendTo($('#content'));
That way, you can do a simple "waitForTextPresent" to see if things worked out and its much more reliable than guessing the browser's loading state. The testmarker class needs to be formatted in a way that it is not visible to the user (e.g. font color == background color).
Thanks for all your comments. After some deeper digging on the net and
in our tests I finally found combining these statements instead of a
simple waitForPageToLoad to be the cure for our issues:
waitForPageToLoad('')
// wait until all ajax activity has ceased. That check's jQuery's $.active
waitForCondition('selenium.browserbot.getUserWindow().$.active == 0', 5000)
// wait a second for all JS to properly initialize
pause(1000)
There is still a pause in there which is somewhat ugly, but it does
the trick.